Related Experiment Video
Updated: Jun 2, 2026

2D-HPLC-MS Technology Combined with Molecular Network for the Identification of Components in Tibetan Medicine Aconitum pendulum
Published on: December 8, 2023
Two-dimensional supercritical fluid chromatography/mass spectrometry for the enantiomeric analysis and purification
Lu Zeng1, Rongda Xu, Yinong Zhang
1Takeda San Diego, Inc., San Diego, CA 92121, USA. lu.zeng@takedasd.com
Abstract:
A new analytical two-dimensional supercritical fluid chromatography/mass spectrometry system (2D SFC/SFC/MS) has been designed and implemented to enhance the efficiency and quality of analytical support in drug discovery. The system consists of a Berger analytical SFC pump and a modifier pump, a Waters ZQ 2000 mass spectrometer, a set of switching valves, and a custom software program. The system integrates achiral and chiral separations into a single run to perform enantiomeric analysis and separation of a racemic compound from a complex mixture without prior clean up. The achiral chromatography in the first dimension separates the racemate from all other impurities, such as un-reacted starting materials and by-products. Mass-triggered fractionation is used to selectively fractionate the targeted racemic compound based on its molecular weight. The purified racemate from the achiral chromatography in the first dimension is then transferred to the chiral column in the second dimension to conduct the enantiomeric separation and analysis. A control software program, we coined SFC2D, was developed and integrated with MassLynx to retrieve acquisition status, current sample information, and real time mass spectrometric data as they are acquired. The SFC2D program also monitors the target ion signal to carry out mass-triggered fractionation by switching the valve to fractionate the desired peak. The 2D SFC/SFC/MS system uses one CO(2) pump and one modifier pump for both first and second dimension chromatographic separations using either gradient or isocratic elution. Similarly, a preparative 2D SFC/SFC/MS system has been constructed by modifying an existing Waters preparative LC/MS system. All components except the back pressure regulator are from the original LC/MS system. Applications of the 2D SFC/SFC/MS methods to the separation and the analysis of racemic pharmaceutical samples in complex mixtures demonstrated that an achiral separation (in first dimension) and a chiral separation (in second dimension) can be successfully combined into a single, streamlined process both in analytical and preparative scale.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Ion-Exchange Chromatography
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...