Comparison of complete versus incomplete stent frame expansion after transcatheter aortic valve implantation with Medtronic CoreValve bioprosthesis
Related Experiment Video
Updated: Jun 2, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Hasan Jilaihawi1, Derek Chin, Tomasz Spyt
1Cedars-Sinai Heart Institute, Los Angeles, California, USA.
Abstract:
We sought to determine the significance of incomplete stent frame expansion after transcatheter aortic valve implantation with the Medtronic-CoreValve device. Incomplete coronary stent expansion is a well-described phenomenon. Transcatheter valves are mounted on stents; however, the incidence of incomplete stent expansion after transcatheter aortic valve implantation, its sequelae and predictors are poorly elucidated. The 18Fr CoreValve revalving system was used to treat anatomically and clinically suitable patients with severe calcific aortic stenosis. The postdeployment stent dimensions were measured on fluoroscopic images at multiple levels of the stent frame. Incomplete expansion at each was defined as <100% expected and complete expansion as ≥100%. These parameters were correlated to the hemodynamic and clinical end points. A total of 50 consecutive patients underwent transcatheter aortic valve implantation with the Medtronic-CoreValve at a single center from January 2007 to December 2008. For the inflow portion, incomplete expansion was seen in 54% of patients and was unrelated to the aortic valve area, peak or mean aortic valve gradients, or measures of aortic regurgitation, although it was paradoxically associated with a lower incidence of prosthesis-patient mismatch. Incomplete expansion of the constrained portion was seen in 62% of the patients and displayed a trend toward a greater incidence of aortic regurgitation grade 2 or greater, although this was rare. Incomplete expansion of the Medtronic CoreValve stent frame is common. For the most part, valvular hemodynamic function was satisfactory, regardless of the degree of expansion of the stent frame that carries it and a strategy of reluctant postdilation in the context of incomplete stent frame expansion was supported.
Related Concept Videos
Mitral Stenosis I: Introduction
Aortic Regurgitation I: Introduction
Acute Coronary Syndrome III: Diagnostic Studies
Mitral Valve Prolapse I: Introduction
Mitral Stenosis III: Medical Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...