Related Experiment Video
Updated: Jun 2, 2026

A Novel Approach for the Administration of Medications and Fluids in Emergency Scenarios and Settings
Published on: November 9, 2016
Use of the Attain Select II catheter delivery system to improve
Xian-hui Zhou1, Bao-peng Tang, Jin-xin Li
1Heart Center, First Affiliated Hospital, Xinjiang Medical University, Urumqi, Xinjiang, China.
Background:
Despite technical advances in tools used to facilitate implantation of cardiac resynchronization therapy (CRT) devices, there are many hurdles related mainly to the variation in the anatomy of the coronary veins. One such difficulty is the presence of a very sharply-angulated or tortuous of the lateral or posterolateral cardiac vein.
Methods:
Totally 44 patients, 28 males and 16 females, with congestive heart failure and intraventricular conduction delay were studied retrospectively. There were 23 patients who had left ventricular (LV) lead implantation using standard techniques and equipment. For the other 21 patients with LV lead implantation we used the Attain Select II catheter delivery system. The patients were seen every 3 - 6 months for 12 months and the efficacy of the primary procedure, LV lead implantation time, procedure and fluoroscopy time and the complications associated with the two techniques were evaluated.
Results:
There were no significant differences in the age, gender, New York Heart Association (NYHA) functional class, ischemic etiology, QRS duration, left ventricular ejection fraction, left ventricular end-diastolic diameter, left ventricular end-systolic diameter and LV dyssynchrony between the two groups. The LV lead implantation time, procedure time and fluoroscopy time were significantly shorter in the group using the Attain Select II catheter delivery system; LV lead implantation time from (51 ± 7) minutes to (40 ± 7) minutes (P < 0.001), procedure time from (143 ± 17) minutes to (124 ± 18) minutes (P = 0.001), and fluoroscopy time from (45 ± 7) minutes to (35 ± 6) minutes (P < 0.001). A successful procedure of LV lead implantation was significantly improved from 17/23 (74%) patients using the standard techniques and equipment, to 20/21 (95.3%) patients using the Attain Select II catheter delivery system (P = 0.06)
Conclusion:
It is feasible and safe to implant LV leads through the coronary sinus using the Attain Select II catheter delivery system.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...

