Related Experiment Video
Updated: Jun 1, 2026

Sampling and Pretreatment of Tooth Enamel Carbonate for Stable Carbon and Oxygen Isotope Analysis
Published on: August 15, 2018
A strategy for selection of reference materials in stable oxygen isotope analyses of solid materials
Grzegorz Skrzypek1, Rohan Sadler
1West Australian Biogeochemistry Centre and John de Laeter Centre of Mass Spectrometry, School of Plant Biology, The University of Western Australia, 35 Stirling Highway (MO90), Crawley, WA 6009, Australia. Grzegorz.Skrzypek@uwa.edu.au
Abstract:
The propagation of uncertainties associated with the stable oxygen isotope reference materials through a multi-point normalisation procedure was evaluated in this study using Monte Carlo (MC) simulation. We quantified the normalisation error for a particular selection of reference materials and their number of replicates, when the choice of standards is restricted to either nitrates, sulphates or organic reference materials alone, and in comparison with when this restriction was relaxed. A lower uncertainty in stable oxygen isotope analyses of solid materials performed using High-Temperature Pyrolysis (HTP) can be readily achieved through an optimal selection of reference materials. Among the currently available certified reference materials the best performing pairs minimising the normalisation errors are USGS35 and USGS34 for nitrates; IAEA-SO-6 and IAEA-SO-5 for sulphates; and IAEA-601 and IAEA-602 for organic materials. The normalisation error can be reduced further--by approximately half--if each of these two analysed reference materials is replicated four times. The overall optimal selection among all nine considered reference materials is the IAEA-602 and IAEA-SO-6 pair. If each of these two reference materials is replicated four times the maximum predicted normalisation error will equal 0.22‰, the minimum normalisation error 0.12‰, and the mean normalisation error 0.15‰ over the natural range of δ(18)O variability. We argue that the proposed approach provides useful insights into reference material selection and in assessing the propagation of analytical error through normalisation procedures in stable oxygen isotope studies.
More Related Videos
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Mass Spectrometry: Isotope Effect

