Related Experiment Video
Updated: Jun 1, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Novel, portable, cassette-sized, and wireless flat-panel digital radiography system: initial workflow results versus
Thomas Lehnert1, Nagy N Naguib, Hanns Ackermann
1Department of Diagnostic and Interventional Radiology, Clinic of Johann Wolfgang Goethe-University, Theodor-Stern-Kai 7, 60590 Frankfurt, Germany. thomas.lehnert@kgu.de
Objective:
The purpose of this article is to compare workflow efficiency between a conventional computed radiography (CR) system and a novel, portable, cassette-sized, and wireless flat-panel digital radiography (DR) system.
Materials And Methods:
Observational time-motion analyses were performed at one site at which CR and the new portable DR system are used concurrently. The workflow steps of both systems were identified and categorized to facilitate comparison. The times required for examination preparation, patient positioning, exposure, postacquisition processing, and the examination as a whole were recorded by a neutral observer. Timing differences between the CR and portable DR systems were compared, and all data were analyzed using commercially available statistical software. Nine general radiographic examination types were selected, with approximately 50 patients per examination type.
Results:
A total of 941 examinations (CR, n = 474; portable DR, n = 467) were timed in this study. Total examination time differences between CR and portable DR system (mean, 26.44 seconds; median 26.99 seconds) were found to be statistically significant (p < 0.001), with DR proving faster than CR. The single largest contributor to the time difference between CR and portable DR was postacquisition processing (mean, 26.58 seconds; median, 25.91 seconds), which was a composite of multiple individual steps, including cassette transport (CR only, mean, 13.22 seconds; median, 12.74 seconds), cassette readout (mean, 10.15 seconds; median, 10.4 seconds), and postprocessing (mean, 3.21 seconds; median, 3.11 seconds).
Conclusion:
Overall radiographer time was significantly shorter when performing examination-related tasks with the novel, portable DR system than when performing comparable tasks with the CR system, a difference that appears to result largely from technology configuration.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...