Objectives:
To investigate the conditions under which the Tofts, extended Tofts, and adiabatic approximation to the tissue homogeneity (AATH) model are the optimal tracer kinetic models (TKMs) for the quantification of dynamic contrast-enhanced (DCE) computed tomography (CT) examinations in prostate cancer.
Materials And Methods:
This prospective study was approved by the local research ethics committee, and all patients gave written informed consent. A total of 29 patients (mean age, 69.1 years; range, 56-80 years) with biopsy-proven prostate cancer underwent a DCE-CT examination prior to radiation therapy. TKM parameter maps were calculated for each patient with the Tofts, extended Tofts, and AATH models. For each voxel, corrected Akaike information criterion values were calculated, taking into account both the goodness-of-fit and the number of model parameters. We consider the optimal model as the model with the lowest corrected Akaike information criterion.
Results:
All 3 TKMs are the optimal models in part of the prostate. For individual patients, the AATH model was the optimal model in 25.0% to 88.9%, the Tofts in 2.7% to 71.8%, and the extended Tofts model in 0.7% to 68.7% of the prostate voxels. The Tofts model was optimal in low flow regions (<0.1 min-1), the extended Tofts model in regions with high flow (>0.4 min-1) and low transit time (<12 seconds), and the AATH model in the intermediate flow range (0.1-0.4 min-1). However, differences between the 3 models were small and TKM parameter estimates gave consistent results between the 3 models.
Conclusions:
All the 3 models gave reasonable fits of DCE-CT data from the prostate. In view of the small parameter range in which the Tofts and extended Tofts models outperform the AATH model, the latter seems the optimal model for quantification of DCE-CT data of the prostate.
More Related Videos
06:24Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
Published on: April 18, 2015
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET