Graphite-Poly(tetrafluoroethylene) Composite Enzyme Electrodes as Suitable Biosensors in Predominantly Nonaqueous
G Ortiz1, M C González, A J Reviejo
1Department of Analytical Chemistry, Faculty of Chemistry, Complutense University of Madrid, 28040 Madrid, Spain, and Department of Analytical Chemistry, University of Alcalá de Henares, 28871-Alcalá de Henares, Madrid, Spain.
Abstract:
The performance of a graphite-poly(tetrafluoroethylene) Teflon composite amperometric ferrocyanide-mediated peroxidase electrode in a predominantly nonaqueous medium such as reversed micelles is discussed and compared with the behavior in a medium formed by acetonitrile/water. The composite electrode was constructed by purely physical entrapment of both the enzyme and the mediator into the bulk of the graphite-Teflon matrix with no need of covalent attachments. This biosensor responded rapidly to the changes in the concentration of both hydrogen peroxide and 2-butanone peroxide in reversed micelles formed with ethyl acetate, 0.1 mol L(-)(1) dioctyl sulfosuccinate as the surfactant, and a 4% phosphate buffer (pH 7.4) as the dispersed phase. The electrode showed a long-term operation due to the renewability of its surface. Moreover, reproducible responses were obtained with different electrodes fabricated from different composite matrixes. No significant loss of the enzyme activity was observed after four months of dry storage at 4 °C of the composite electrode. Limits of detection of 2.1 × 10(-)(7) and 3.5 × 10(-)(7) mol L(-)(1) were obtained for H(2)O(2) and 2-butanone peroxide, respectively. The possibility of using this biocomposite electrode in flowing systems, using the reversed micelles as the carrier, has been demonstrated. The kinetic of the enzymatic reaction was faster in a 90:10 acetonitrile/phosphate buffer medium than in reversed micelles, which can be attributed to the higher water content present in the former medium. A similar stability of the biosensor and a slightly better sensitivity for peroxides was observed in the acetonitrile/water mixture when compared with reversed micelles. Finally, the electrode also performed well in the flow injection mode.
More Related Videos
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
13:42Dry Film Photoresist-based Electrochemical Microfluidic Biosensor Platform: Device Fabrication, On-chip Assay Preparation, and System Operation
Published on: September 19, 2017