Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor
Published on: April 6, 2016
Characterization of reaction dynamics in a trypsin-modified capillary microreactor
1Department of Chemistry, University of California, Riverside, California 92521.
Abstract:
Application of mild vibration to an immobilized trypsin capillary microreactor can enhance digestion rates for many globular and glycosylated proteins (12-70-kDa range) without additional sample handling. A sinusoid wave form generator and a simple piezoelectric transducer were used to apply vibration in a wide frequency range to the 50-μm-i.d. enzyme microreactor over its entire length. The mass transport properties of the microreactor were quantitatively examined for protein digestions through the use of an artificial globular protein. This was synthesized by covering the surface of 35-nm-diameter latex beads with a peptide (Leu-Arg-Leu). Capillary electrophoresis analysis of the microreactor products showed there were no mass transport-related effects for vibration of the capillary. Digestions of a range of globular protein structures were performed and the products analyzed by capillary electrophoresis. The rate enhancements were found to be related to the stability of the protein tertiary and secondary structure. Cytochrome c showed a dramatic acceleration in rate of digestion as the vibration frequency increased over a range of 200 Hz to 7.1 kHz. The ability to enhance reaction rates for very stable proteins can be gained by additional means of destabilizing the protein, as shown by removal of calcium from α-lactalbumin. Vibration of the enzyme capillary will have the greatest utility for extremely limited protein samples since chemical modification to completely denature proteins usually requires considerable sample handling.
More Related Videos
09:56Real-time Monitoring of Reactions Performed Using Continuous-flow Processing: The Preparation of 3-Acetylcoumarin as an Example
Published on: November 18, 2015
14:43Microfluidic On-chip Capture-cycloaddition Reaction to Reversibly Immobilize Small Molecules or Multi-component Structures for Biosensor Applications
Published on: September 23, 2013
Related Concept Videos
Fast Reactions
Measuring Reaction Rates
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...