Related Experiment Video
Updated: Jun 1, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Monolithic capillary columns synthesized from a single phosphate-containing dimethacrylate monomer for
Xin Chen1, H Dennis Tolley, Milton L Lee
1Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA.
Abstract:
Monoliths containing phosphoric acid functional groups were synthesized from only one monomer, bis[2-(methacryloyloxy)ethyl] phosphate (BMEP), in 75-μm i.d. UV transparent fused-silica capillaries by photo-initiated polymerization for cation exchange chromatography of peptides and proteins. Various synthetic conditions, including porogen solvents, monomer concentration, and polymerization time, were studied. The hydrophobicities of the resulting monoliths were evaluated using propyl paraben under reversed-phase conditions and synthetic peptides under ion-exchange conditions. These monoliths exhibited low hydrophobicities and relatively low porosities due to their highly cross-linked structures. A dynamic binding capacity (lysozyme) of 73 mg/mL of column volume was measured using the best performing monolith. Synthetic peptides were eluted in approximately 30 min without addition of acetonitrile to the mobile phase, yielding a peak capacity of 28. Efficiencies of 52,900 plates/m for peptides and 71,000 plates/m for proteins were obtained under isocratic conditions. The effects of separation conditions, i.e., mobile phase pH and salt gradient rate, were studied. Good run-to-run reproducibility was achieved with a relative standard deviation (RSD) less than 1.5% for retention times of proteins. The column-to-column retention time reproducibility for peptides was less than 3.5% RSD. A monolithic column was used to follow the deamidation of ribonuclease A. The kinetics of deamidation were founded to be first order with a half life of 195 h. A cytochrome C digest was also separated using a linear gradient of sodium chloride.
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Affinity Chromatography

