Related Experiment Video
Updated: May 31, 2026

Determining Four Components in a Lipid Nanoparticle RNA Delivery System by Liquid Chromatography Combined with Evaporative Light Scattering Detector
Published on: May 30, 2025
Development and validation of a stability-indicating LC method for determining palonosetron hydrochloride, its
M Vishnu Murthy1, Katkam Srinivas, Ramesh Kumar
1Analytical Research and Development, Integrated product development operations, Dr. Reddy's Laboratories Ltd., Bachupally, Qutubullapur, R.R. Dist. 500072, Andhra Pradesh, India. vishnu.drl@gmail.com
Abstract:
A selective and simple reversed phase HPLC method using naphthalethyl stationary phase was developed and validated for the quantitative determination of palonosetron hydrochloride (PALO), its related compounds and degradation products. Chromatographic separation (R(s)>2) was achieved with linear gradient mode of elution at a flow rate of 1 mL/min and with UV detection at 210 nm. The intra and inter-day coefficients of variation were less than 1.0% (RSD). Consistent recoveries were obtained for PALO (99.2-100.5%) and its impurities (90.0-104.8%). All the analytes exhibited excellent linearity with R² value greater than 0.998. Limit of detection (LOD) and limit of quantification (LOQ) were determined to be in the range 0.011-0.013 μg/mL and 0.035-0.046 μg/mL respectively. The test solution was found to be stable up to 5 days. Induced degradation methods were applied to study the degradation behavior of the drug. LC-MS was used to analyze the degraded samples and possible structural identifications were assigned based upon known reactivity of the drug and molecular weights. The m/z values matched with the hydroxylated, keto and N-oxide metabolites of PALO. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.9%.
More Related Videos
07:11Automated HPLC Separation Using LC-Mate: An Integrated Repetitive Autosampler and Fraction Collector for Microscale Purification
Published on: February 27, 2026
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
Related Concept Videos
Drug Product Stability
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Instrumentation
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence