Related Experiment Video
Updated: May 30, 2026

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Bivariate phase-rectified signal averaging for assessment of spontaneous baroreflex sensitivity: normalization of the
Alexander Müller1, Adrian Morley-Davies, Petra Barthel
11. Medizinische Klinik und Deutsches Herzzentrum München der Technischen Universität München, München, Germany.
Background:
Previously proposed technique for assessment of spontaneous baroreflex sensitivity (BRS) based on bivariate phase-rectified signal averaging measures averaged R-R interval (RRI) changes triggered by beat-to-beat increases in systolic blood pressure (SBP). In this study, we investigate a normalized version of the method that relates the averaged RRI changes to the triggering blood pressure changes, thus providing the results in measurement units comparable with existing literature.
Methods:
Data of previously reported prospective observational study were used. In each of 146 heart failure patients presenting with sinus rhythm, 10-minute recordings of electrocardiogram and arterial and blood pressures were obtained in the supine resting position. The averaged RRI increases initiated by beat-to-beat SBP increases were measured (original BRS result in milliseconds) and normalized for the averaged beat-to-beat SBP increases (normalized BRS result in milliseconds per millimeters of mercury). Both results were compared in terms of predicting all-cause mortality during a mean follow-up of 2.7 ± 1.1 years when 42 patients (28.8%) died.
Results:
Both types of results were highly correlated (r = 0.938, P < .001) and led to similarly strong separation of high- and low-risk groups. The receiver operator characteristics of both indices were well within the 95% confidence intervals of each other, and the areas under the characteristics were practically identical: 71.1% (95% confidence interval, 60.7%-80.9%) for original BRS and 69.7% (58.9%-79.2%) for normalized BRS.
Conclusion:
The results might question the concept of a linear relationship between the SBP changes and RRI changes. The phase-rectified signal averaging-based assessment of BRS may be used with equal legitimacy in the nonnormalized and normalized forms; the normalized form provides results in conventional measurement units.
More Related Videos
11:08Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.
Published on: February 14, 2018
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure