Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
Color and power Doppler US for diagnosing carpal tunnel syndrome and determining its severity: a quantitative image
Ahmad Reza Ghasemi-Esfe1, Omid Khalilzadeh, Seyed Mehran Vaziri-Bozorg
1Advanced Diagnostic and Interventional Radiology Research Center, Imam Hospital, Tehran University of Medical Sciences, Keshavarz Blvd, Tehran 13145-784, Iran.
Purpose:
To determine whether intraneural vascularity seen at color Doppler ultrasonography (US) can be used to diagnose carpal tunnel syndrome (CTS) and to evaluate an image processing method for quantifying the severity of CTS on the basis of this vascularity.
Materials And Methods:
This study was approved by the university ethics review committee. One hundred one patients with clinical evidence of CTS and 55 healthy control subjects were enrolled. Electrodiagnostic testing (EDT) was performed in all participants, and the presence of intraneural vascularity was evaluated with color Doppler US. An image processing program was designed by using software to determine the sum of pixels in the intraneural vascular area on power Doppler US scans of the median nerve. The relationship between the number of pixels and the severity of the abnormality at EDT was determined.
Results:
The sensitivity (83%) and specificity (89%) of intraneural vascularity in the diagnosis of CTS were similar to those of EDT (81% and 84%, respectively). Intraneural vascularity was seen in 91.4% of patients with mild CTS and 100% of patients with moderate or severe CTS. In participants with positive intraneural vascularity, the sum of pixels in the intraneural vascular area was significantly higher in patients than in control subjects and paralleled the severity of the abnormality at EDT (P < .01).
Conclusion:
Color Doppler US can be used to accurately diagnose CTS. By processing the recorded power Doppler images and determining the number of pixels in the intraneural vascular area, the severity of CTS can be assessed. 2011 SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11110150/-/DC1.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation