Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Improving detection and figures of merit in single-particle inductively coupled plasma-mass spectrometry via transient event heights.

Analytica chimica acta·2025
Same author

Discrete Entity Analysis via Microwave-Induced Nitrogen Plasma-Mass Spectrometry in Single-Event Mode.

Analytical chemistry·2025
Same author

Ions with Ions, Entities with Entities: A Proof-of-Concept Study Using the SELM-1 Yeast Certified Reference Material for Intra- and Extracellular Se Quantification via Single-Cell ICP-Mass Spectrometry.

Analytical chemistry·2025
Same author

LAMIS in the gas phase: A new approach for obtaining Ca elemental and isotopic information via CaF molecule formation.

Talanta·2025
Same author

Intensity- and time-based strategies for micro/nano-sizing via single-particle ICP-mass spectrometry: A comparative assessment using Au and SiO<sub>2</sub> as model particles.

Analytica chimica acta·2024
Same author

Tracing isotopically labeled selenium nanoparticles in plants via single-particle ICP-mass spectrometry.

Talanta·2024
Same journal

Single-cell mass spectrometry imaging: platform advances for multimodal spatial omics.

Analytical and bioanalytical chemistry·2026
Same journal

Advancing total uronic acid quantification using a stable isotope dilution approach: validation and application to plant- and algal-derived polysaccharides.

Analytical and bioanalytical chemistry·2026
Same journal

Electroanalytical method development for the receptor tyrosine kinase inhibitor lenvatinib using a Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>-MXene based molecularly imprinted polymer modified carbon electrode.

Analytical and bioanalytical chemistry·2026
Same journal

Impact of blood contamination on hydrophilic metabolomics in human meningioma tissue.

Analytical and bioanalytical chemistry·2026
Same journal

A UiO-66@MR paper-based colorimetric sensor for sensitive detection of food spoilage volatile organic compounds and visual freshness monitoring.

Analytical and bioanalytical chemistry·2026
Same journal

An electrochemical sensing platform based on UiO@TATF COF/CB composites for the detection of nitrofurazone.

Analytical and bioanalytical chemistry·2026
See all related articles

Related Experiment Video

Updated: May 29, 2026

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
07:17

Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry

Published on: August 1, 2017

Plasma spectrochemistry

Juan R Castillo, Martín Resano

    Analytical and Bioanalytical Chemistry
    |September 13, 2011
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
    06:46

    Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic

    Published on: August 25, 2016

    A Plasma Sample Preparation for Mass Spectrometry using an Automated Workstation
    07:12

    A Plasma Sample Preparation for Mass Spectrometry using an Automated Workstation

    Published on: April 24, 2020

    Related Experiment Videos

    Last Updated: May 29, 2026

    Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry
    07:17

    Non-equilibrium Microwave Plasma for Efficient High Temperature Chemistry

    Published on: August 1, 2017

    Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
    06:46

    Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic

    Published on: August 25, 2016

    A Plasma Sample Preparation for Mass Spectrometry using an Automated Workstation
    07:12

    A Plasma Sample Preparation for Mass Spectrometry using an Automated Workstation

    Published on: April 24, 2020