Related Experiment Video
Updated: May 28, 2026

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Published on: August 24, 2018
Depth deviation and occurrence of early surgical complications or unexpected events using a single stereolithographic
M Cassetta1, L V Stefanelli, M Giansanti
1Department of Oral and Maxillo-facial Sciences, School of Dentistry, Sapienza University of Rome, Italy. michele.cassetta@uniroma1.it
Abstract:
The purpose of this study was to determine the accuracy of depth implant insertion and to describe the frequency of early surgical complications or unexpected events, recorded using a single, totally guided, stereolithographic surgi-guide (bone-, mucosa- and teeth-supported) for both osteotomy site preparation and implant delivery. Ten adults were included in this study. Six patients were treated in both arches, and the number of computer aided implantology (CAI) interventions was 16, which equalled the number of guides used, for a total of 111 implants inserted. Complications and unexpected events occurred during the positioning of the surgical guide and whilst preparing the implant site and installing implants. In order to minimize the risk of complications and unexpected events, attention must be paid to every stage of treatment, including checking computed tomography (CT) images, guide manufacturing, proper guide positioning in the mouth, guide fixation, rotational allowance of drill in tubes, shape and sharpness of the drills, first entry point, mouth opening and guided implant insertion.