Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: May 28, 2026

Echocardiographic Measurement of Right Ventricular Diastolic Parameters in Mouse
06:04

Echocardiographic Measurement of Right Ventricular Diastolic Parameters in Mouse

Published on: April 27, 2019

Ventricular function during exercise in mice and rats.

Heidi L Lujan1, Hussein Janbaih, Han-Zhong Feng

  • 1Department of Physiology, Wayne State University School of Medicine, Detroit, Michigan 48201, USA.

American Journal of Physiology. Regulatory, Integrative and Comparative Physiology
|October 21, 2011
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Not Starling's first name: acknowledging Otto Frank's legacy in physiology education.

Advances in physiology education·2026
Same author

Thin filament interaction and Ca<sup>2+</sup>-desensitization effect of the C-terminal end peptide of cardiac troponin T and loss of function in hypertrophic cardiomyopathy mutants.

Journal of molecular and cellular cardiology·2026
Same author

When causality becomes elegant: from mechanism to meaning in physiology.

Advances in physiology education·2026
Same author

The illusion of learning: turning studying into thinking.

Advances in physiology education·2025
Same author

Systolic-dominant coronary flow in rats and mice: Challenging the diastolic paradigm across conscious and anaesthetized states.

Experimental physiology·2025
Same author

Making the invisible visible: exploring cardiovascular regulation with a simple analog blood pressure model.

Advances in physiology education·2025

This study introduces a new telemetry method for measuring left ventricular (LV) function in conscious mice during rest and exercise. This technique enables detailed cardiac function assessment in freely moving animals, advancing cardiovascular research.

Area of Science:

  • Cardiovascular physiology
  • Animal models in research

Background:

  • Mice are valuable models for studying left ventricular (LV) function.
  • A need exists for conscious, freely moving mouse models to assess cardiac function.
  • Existing methods often lack the ability to measure cardiac function in unrestrained, conscious animals.

Purpose of the Study:

  • To develop and validate a telemetry system for chronic, non-invasive measurement of LV function in conscious mice.
  • To assess LV function at rest and during exercise in mice using this new method.
  • To compare mouse responses to those of instrumented rats.

Main Methods:

  • Implanted telemetry devices (PA-C10) for continuous LV pressure recording in mice.
  • Surgical implantation into the intraperitoneal space (transmitter) and LV (pressure sensor).

More Related Videos

Biventricular Assessment of Cardiac Function and Pressure-Volume Loops by Closed-Chest Catheterization in Mice
08:21

Biventricular Assessment of Cardiac Function and Pressure-Volume Loops by Closed-Chest Catheterization in Mice

Published on: June 15, 2020

Related Experiment Videos

Last Updated: May 28, 2026

Echocardiographic Measurement of Right Ventricular Diastolic Parameters in Mouse
06:04

Echocardiographic Measurement of Right Ventricular Diastolic Parameters in Mouse

Published on: April 27, 2019

Biventricular Assessment of Cardiac Function and Pressure-Volume Loops by Closed-Chest Catheterization in Mice
08:21

Biventricular Assessment of Cardiac Function and Pressure-Volume Loops by Closed-Chest Catheterization in Mice

Published on: June 15, 2020

  • Recovery period, acclimatization to laboratory and treadmill, followed by rest and graded exercise testing.
  • Main Results:

    • Successfully demonstrated serial assessment of ventricular function during exercise in conscious mice.
    • Provided reference data by comparing responses in mice to identically instrumented conscious rats.
    • Established a reliable method for nontethered recordings of pulsatile LV pressure.

    Conclusions:

    • The developed telemetry methodology allows for the first time serial assessment of cardiac function in conscious, exercising mice.
    • This technique offers a valuable tool for advancing cardiovascular research and understanding LV function.
    • The method is adaptable for further studies in cardiovascular physiology and disease models.