Characteristic impedance and capacitance analysis of Blumlein type pulse forming line of accelerator based on tape

Yu Zhang1, Jinliang Liu, Xuliang Fan

  • 1College of Opto-electronic Science and Engineering, National University of Defense Technology, Changsha, 410073, China.

Related Concept Videos

Capacitance: Single-Phase And Three-Phase Line01:25

Capacitance: Single-Phase And Three-Phase Line

In electrical power systems, understanding the capacitance of transmission lines is fundamental for efficient operation.
Single-Phase Lines
Consider a single-phase, two-wire transmission line with equal phase spacing energized by a voltage source. One conductor carries a uniform positive charge, while the other carries an equal negative charge. The capacitance C of the line can be derived from the voltage V between the conductors. For a one-meter section of the line, the capacitance is given...
Lossless Lines01:23

Lossless Lines

In electrical engineering, a lossless transmission line is characterized by a purely imaginary propagation constant and a resistive characteristic impedance. The ABCD parameters, which describe the relationship between the input and output voltages and currents, indicate an equivalent π circuit with an imaginary series impedance and a shunt admittance. This results in a transmission line that, when the product of the phase constant (beta) and the length of the line is less than pi, exhibits...
Mesh Analysis for AC Circuits01:12

Mesh Analysis for AC Circuits

In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Traveling Waves: Lossless Lines01:27

Traveling Waves: Lossless Lines

The provided content explores the behavior of traveling waves on single-phase lossless transmission lines. It begins with a single-phase two-wire lossless transmission line of length Δx, characterized by a loop inductance LH/m and a line-to-line capacitance C F/m. These parameters result in a series inductance LΔx and a shunt capacitance CΔx.
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
Inductance: Single-Phase And Three-Phase Line01:28

Inductance: Single-Phase And Three-Phase Line

Understanding the inductance of transmission lines is crucial for efficient design and operation in electrical power systems. This discussion delves into the inductance characteristics of single-phase two-wire and three-phase three-wire transmission lines with equal phase spacing.
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...