Related Experiment Video
Updated: May 26, 2026

Quantitative Analysis of Viscoelastic Properties of Red Blood Cells Using Optical Tweezers and Defocusing Microscopy
Published on: March 25, 2022
Whole blood viscosity extrapolation formula: Note on appropriateness of units
Ezekiel Uba Nwose1, Ross Stuart Richards
1Nepean Hospital Pathology; Derby Street Kingswood, NSW 2747, Australia.
Background:
A series has recently been done on whole blood viscosity. The first on the series proposed extrapolation chart with conventional reference range. Since the publication, two concerns have been received in personal communications. The first expressed concern over the use of serum proteins values in 'g/L' instead of 'g/dL' that was contained in the referenced material. The second enquired on suitability of the formula for determination of blood viscosity at low shear rate.
Aim:
This work sets out to compare different units-converted-modifications of the extrapolation with a view to develop a statement of comparison and suitability of units.
Materials And Methods:
The values of haematocrit and serum proteins were used in different unit-conversions on the mathematical formula to derive four modifications, which were compared. Five clinical cases that were specifically tested for whole blood viscosity, and had results for haematocrit and serum proteins were evaluated. The appropriateness of modifications for determination of viscosity at low shear rate was reviewed.
Results:
Except as modified and used in the series, determination of whole blood viscosity at low shear rate using other unit conversions on the formula yields negative values for all five cases.
Conclusion:
Given that it is unexpected for blood viscosity level to be zero let alone less, it is logical that negative values are invalid. A formula that gives the least invalid results may be most appropriate. Therefore, extrapolation modification used in the series is most appropriate.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
Related Concept Videos
Viscosity
Viscosity
The SI unit of viscosity is...
Applications of Integration to Find Blood Flow
Stokes' Law
The expression for the force on a solid spherical object in a fluid is called Stokes' law. Stokes' law is valid only for low Reynolds...
Viscosity of Fluid
Newtonian Fluid: Problem Solving
A velocity gradient forms within the fluid when a Newtonian fluid is placed between two parallel plates, with...