Related Experiment Video
Updated: May 26, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Liquid-phase microextraction and desorption electrospray ionization mass spectrometry for identification and
Janina Thunig1, Linda Flø, Stig Pedersen-Bjergaard
1Department of Pharmaceutics and Analytical Chemistry, University of Copenhagen, Universitetsparken 2, Copenhagen 2100, Denmark.
Abstract:
Hollow fibre liquid-phase microextraction (LPME) and desorption electrospray ionization mass spectrometry (DESI-MS) were evaluated for the identification and quantification of basic drugs in human urine samples. The selective extraction capabilities of three-phase LPME provided a significant reduction in the matrix effects otherwise observed in direct DESI-MS analysis of urine samples. Aqueous LPME extracts (in 10 mM HCl) were deposited on porous Teflon, dried at room temperature, and the dried spots were then analyzed directly with DESI-MS in full scan mode. Pethidine, diphenhydramine, nortriptyline, and methadone were used as model compounds for identification, and their limits of identification were determined to be 100, 25, 100, and 30 ng/mL, respectively. In a reliability test with 19 spiked urine samples, 100% of the positive samples containing the model drugs in concentrations at or above the limit of identification were identified. Diphenhydramine was used as a model compound for quantitative analysis with diphenhydramine-d(5) as an internal standard. The calibration curve was linear in the range 50-2000 ng/mL (R(2) = 0.992) with a limit of quantification at approximately 140 ng/mL. The intra- and inter-day relative standard deviations were <9.5%. In a reliability test with six spiked urine samples, deviations between the measured and the true values for diphenhydramine were in the range 0.2-22.9%.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Performance Liquid Chromatography: Types of Detectors
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...