Advances in pump technology: insulin patch pumps, combined pumps and glucose sensors, and implanted pumps
P Schaepelynck1, P Darmon, L Molines
1Service d'endocrinologie, nutrition et maladies métaboliques, CHU-Hôpitaux sud, 270, Boulevard de Sainte Marguerite, 13009 Marseille, France. pauline.schaepelynck@ap-hm.fr
Abstract:
This review discusses the most recent developments in insulin pump technology. The benefits of the insulin pump to patients with type 1 diabetes are recognized both for its metabolic effectiveness and its positive effects on quality of life. The current pumps are reliable, small and light, and are becoming more and more sophisticated. Nevertheless, there remain practical and psychological constraints for the patient. However, recent patch-pump advances should simplify the technical aspects of pump treatment and enhance patient comfort. Another advance combines the insulin pump with a glucose sensor. Such a combination is logical for optimizing pump use and, to that end, developing an automated or 'closed-loop'system that permits the delivery of subcutaneous insulin adjusted according to measured levels of subcutaneous glucose. Finally, implanted insulin pumps have proven their worth not only because of their simple use, but also for their contribution in the artificial pancreas project. Indeed, the prompt response with intraperitoneal administration of insulin makes it of interest for use in a closed-loop system.
More Related Videos
08:04Human Pseudoislet System for Synchronous Assessment of Fluorescent Biosensor Dynamics and Hormone Secretory Profiles
Published on: November 3, 2023
08:32Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain
Published on: January 4, 2018
Related Concept Videos
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into rapid-acting...
Parenteral Drug Delivery Systems: Injectables, Implants, and Infusion Devices
Glucagon-like Receptor Agonists
GLP-1, when administered in high doses intravenously, triggers insulin secretion, inhibits glucagon release, slows gastric emptying, reduces food intake, and restores normal insulin secretion. However, its rapid inactivation by the...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion
Insulin and C-peptide are co-secreted in...
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment primarily uses...