Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Influence of synthesis temperature of eggshell-derived hydroxyapatite on biofilm formation and microbial fuel cell performance.

Bioelectrochemistry (Amsterdam, Netherlands)·2026
Same author

Temperature-driven changes in biofilm formation and electrochemical performance of deep-sea inoculum in microbial fuel cells.

Bioelectrochemistry (Amsterdam, Netherlands)·2025
Same author

Exploring the role of domesticated resistors in batch-mode microbial desalination cell.

Chemosphere·2024
Same author

Optimal aeration area of cathode electrode in the batch type of microbial fuel cells with non-woven interface.

Chemosphere·2023
Same author

Impact of Cross-Validation on Machine Learning Models for Early Detection of Intrauterine Fetal Demise.

Diagnostics (Basel, Switzerland)·2023
Same author

Computational Intelligence in Cancer Diagnostics: A Contemporary Review of Smart Phone Apps, Current Problems, and Future Research Potentials.

Diagnostics (Basel, Switzerland)·2023
Same journal

RETRACTED: Zhang et al. A Novel Framework for Reconstruction and Imaging of Target Scattering Centers via Wide-Angle Incidence in Radar Networks. <i>Sensors</i> 2025, <i>25</i>, 6802.

Sensors (Basel, Switzerland)·2026
Same journal

Enhancing Unsupervised Multi-Source Domain Adaptation for Person Re-Identification via Mixture of Experts and Graph-Based Relation.

Sensors (Basel, Switzerland)·2026
Same journal

Development of an Instrumented Glove for Palmar Pressure Assessment in Kayakers.

Sensors (Basel, Switzerland)·2026
Same journal

Development and Experimental Validation of an Autonomous IoT-Based Monitoring System for Real-Time Water Quality Assessment in the Amazon River.

Sensors (Basel, Switzerland)·2026
Same journal

Semi-Supervised Adversarial Learning Framework for Controller Area Network Bus Intrusion Detection.

Sensors (Basel, Switzerland)·2026
Same journal

Smart Optimization Method for Safety Signs in Innovative Manufacturing Environments Integrating Industrial Field IoT Sensors and Knowledge Graphs.

Sensors (Basel, Switzerland)·2026
See all related articles

Related Experiment Video

Updated: May 24, 2026

Reduced-gravity Environment Hardware Demonstrations of a Prototype Miniaturized Flow Cytometer and Companion Microfluidic Mixing Technology
13:59

Reduced-gravity Environment Hardware Demonstrations of a Prototype Miniaturized Flow Cytometer and Companion Microfluidic Mixing Technology

Published on: November 13, 2014

Biophysical micromixer.

Chin-Tsan Wang1, Yuh-Chung Hu, Tzu-Yang Hu

  • 1Department of Mechanical and Electromechanical Engineering, Center of Green Technology, National I-Lan University, I Lan, 26047, Taiwan; E-Mails: ychu@niu.edu.tw (Y.-C.H.); hour7593@yahoo.com.tw (T.-Y.H.).

Sensors (Basel, Switzerland)
|February 21, 2012
PubMed
Summary
This summary is machine-generated.

This study presents a novel biophysical passive micromixer inspired by vascular networks. It achieves efficient mixing using split and recombination (SAR) within a compact 370 μm space, demonstrating high mixing efficiency across various flow conditions.

Keywords:
biophysical micromixerpassive micromixer

More Related Videos

Microfluidic Mixers for Studying Protein Folding
12:42

Microfluidic Mixers for Studying Protein Folding

Published on: April 10, 2012

Microfluidic Picoliter Bioreactor for Microbial Single-cell Analysis: Fabrication, System Setup, and Operation
12:04

Microfluidic Picoliter Bioreactor for Microbial Single-cell Analysis: Fabrication, System Setup, and Operation

Published on: December 6, 2013

Related Experiment Videos

Last Updated: May 24, 2026

Reduced-gravity Environment Hardware Demonstrations of a Prototype Miniaturized Flow Cytometer and Companion Microfluidic Mixing Technology
13:59

Reduced-gravity Environment Hardware Demonstrations of a Prototype Miniaturized Flow Cytometer and Companion Microfluidic Mixing Technology

Published on: November 13, 2014

Microfluidic Mixers for Studying Protein Folding
12:42

Microfluidic Mixers for Studying Protein Folding

Published on: April 10, 2012

Microfluidic Picoliter Bioreactor for Microbial Single-cell Analysis: Fabrication, System Setup, and Operation
12:04

Microfluidic Picoliter Bioreactor for Microbial Single-cell Analysis: Fabrication, System Setup, and Operation

Published on: December 6, 2013

Area of Science:

  • Biophysics
  • Fluid Dynamics
  • Microfluidics

Background:

  • Traditional passive micromixers often require larger footprints.
  • Mimicking vascular networks offers potential for miniaturized and efficient fluid manipulation.

Purpose of the Study:

  • To design and evaluate a novel biophysical passive micromixer.
  • To investigate mixing enhancement using channel anamorphosis and split-and-recombination (SAR) techniques.
  • To explore the impact of Reynolds number and aspect ratio on mixing performance.

Main Methods:

  • Development of a biophysical passive micromixer with channel anamorphosis (370 μm length).
  • Simulation of fluid flow using split and recombination (SAR) as the primary mixing strategy.
  • Numerical analysis of mixing efficiency (ε) at varying Reynolds numbers (Re = 1-90) and aspect ratios (AR).

Main Results:

  • Achieved high mixing efficiency (ε = 0.876) at a Reynolds number ratio (Re(r)) of 0.85.
  • Demonstrated that increasing Reynolds number generally enhances mixing performance.
  • Identified an optimal aspect ratio (AR = 2) for maximal mixing efficiency (ε = 0.803) due to sidewall effects.

Conclusions:

  • The developed biophysical passive micromixer offers efficient mixing in a reduced space.
  • SAR strategy effectively enhances convection and mixing performance.
  • Findings provide valuable insights for optimizing passive micromixer design for improved mixing efficiency.