Related Experiment Video
Updated: May 23, 2026

Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
A method for accurate temperature measurement using infrared thermal camera
Tomoharu Tokunaga1, Takashi Narushima, Tetsu Yonezawa
1Department of Quantum Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Aichi 464-8603, Japan. t.tokunaga@numse.nagoya-u.ac.jp
Accurate temperature measurement on heated molybdenum foils for electron microscopy is crucial. This study presents a new method to precisely map temperature distribution on samples during heating.
Area of Science:
- Materials Science
- Analytical Chemistry
- Physics
Background:
- Electron microscopy requires precise sample temperature control.
- Measuring temperature distribution on heated samples, especially thin foils, is challenging.
- Existing methods lack accuracy for localized temperature measurements on heated samples.
Purpose of the Study:
- To develop and discuss a method for accurate temperature distribution measurement on heated samples for electron microscopy.
- To address the challenge of temperature drop at the edges of center-holed molybdenum foils.
- To enable precise thermal analysis of samples during electron microscopy experiments.
Main Methods:
- Utilized an infrared thermal camera to measure temperature distribution.
- Employed a center-holed thin foil of molybdenum as the sample.
- Heated the sample using a specialized sample-heating holder for electron microscopy.
Main Results:
- Temperature near the heating stage closely matched the stage temperature.
- Identified a significant temperature drop at the foil edge farthest from the heating stage.
- Demonstrated the necessity of considering temperature gradients in thermal analysis.
Conclusions:
- Accurate, localized temperature measurement on heated samples is achievable with the developed method.
- The method is essential for understanding thermal behavior in electron microscopy.
- This technique will improve the reliability of experiments involving heated samples.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
IR Spectrometers
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...

