Acoustic emission signals can discriminate between compressive bone fractures and tensile ligament injuries in the
C Van Toen1, J Street, T R Oxland
1Orthopaedic and Injury Biomechanics Group, Departments of Mechanical Engineering and Orthopaedics, University of British Columbia, 818 West 10th Avenue, Vancouver, BC, V5Z 1M9, Canada. carolyn@mech.ubc.ca
Abstract:
Acoustic emission (AE) sensors are a reliable tool in detecting fracture; however they have not been used to differentiate between compressive osseous and tensile ligamentous failures in the spine. This study evaluated the effectiveness of AE data in detecting the time of injury of ligamentum flavum (LF) and vertebral body (VB) specimens tested in tension and compression, respectively, and in differentiating between these failures. AE signals were collected while LF (n=7) and VB (n=7) specimens from human cadavers were tested in tension and compression (0.4m/s), respectively. Times of injury (time of peak AE amplitude) were compared to those using traditional methods (VB: time of peak force, LF: visual evidence in high speed video). Peak AE signal amplitudes and frequencies (using Fourier and wavelet transformations) for the LF and VB specimens were compared. In each group, six specimens failed (VB, fracture; LF, periosteal stripping or attenuation) and one did not. Time of injury using AE signals for VB and LF specimens produced average absolute differences to traditional methods of 0.7 (SD=0.2) ms and 2.4 (SD=1.5) ms (representing 14% and 20% of the average loading time), respectively. AE signals from VB fractures had higher amplitudes and frequencies than those from LF failures (average peak amplitude 87.7 (SD=6.9) dB vs. 71.8 (SD=9.8)dB for the inferior sensor, p<0.05; median characteristic frequency from the inferior sensor 97 (interquartile range, IQR, 41) kHz vs. 31 (IQR 2) kHz, p<0.05). These findings demonstrate that AE signals could be used to delineate complex failures of the spine.
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...