Voxel phantoms: the new ICRP computational phantoms: how do they compare?
Kevin Capello1, Stephanie Kedzior, Gary H Kramer
1Human Monitoring Laboratory, National Internal Radiation Assessment Section, Radiation Protection Bureau, Ottawa, Ontario, Canada. kevin.capello@hc-sc.gc.ca
Abstract:
Two new voxel phantoms, ICRP Adult Female (AF) and ICRP Adult Male (AM), have been compared with BOMAB (BOttle Mannikin ABsorber) phantoms and other voxel phantoms of similar size (NORMAN and VIP-Man) using Monte Carlo simulations to assess their counting efficiencies in a whole body counter. The results show that the ICRP phantoms, compared with NORMAN and VIP-Man, had counting efficiencies that ranged from 3% to 59% higher over the energy range 122 keV to 1,836 keV, a trend that is also exhibited by the comparable BOMAB phantoms. A comparison of all the voxel phantoms' results to those of the BOMAB phantom corresponding to reference man shows that the NORMAN and VIP-Man have mostly lower counting efficiencies, whereas the ICRP phantoms have higher counting efficiencies than the PM (Phantom Male) BOMAB phantom. This could be due to differences in the internal structure of each of the voxel phantoms. As expected, the ICRP AF (female voxel) had the highest efficiency due to being the smallest of all the phantoms.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET