Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
The influence of resin flexural modulus on the magnitude of ceramic strengthening
Garry J P Fleming1, Paul Hooi, Owen Addison
1Materials Science Unit, Division of Oral Biosciences, Dublin Dental University Hospital, Trinity College Dublin, Lincoln Place, Dublin 2, Ireland. garry.fleming@dental.tcd.ie
Introduction:
The aim was to determine the magnitude of ceramic resin-strengthening with resin-based materials with varying flexural moduli using a regression technique to assess the theoretical strengthening at a 'zero' resin-coating thickness. The hypothesis tested was that experimentally, increasing resin flexural modulus results in increased resin-strengthening observed at a theoretical 'zero' resin-coating thickness.
Method:
Vitadur Alpha dentin porcelain disk (n=250) were condensed, fired, alumina particle air abraded and randomly assigned into ten groups. Groups were resin-coated at 50, 100 and 150μm with Venus Flow, Rely-X Veneer and Clearfil AP-X before biaxial flexure testing at 24h and the stress at failure calculated using a multilayer analysis. An analytical methodological approach was undertaken to predict the biaxial flexure stresses under boundary conditions that reflected the experimental test and a finite element model was used to verify the analytical prediction.
Results:
The magnitude of resin-reinforcement was significantly influenced by resin-coating type (P<0.001) and resin-coating thickness (P=0.013), however, a significant interaction was observed between resin-coating type and thickness (P=0.048). Linear regression identified a 17, 38 and 47% biaxial flexure strength contribution when Venus Flow, Rely-X Veneer and Clearfil AP-X were used, respectively. The finite element model determined the maximum principal stress was within 3.3% of the predicted analytical solution.
Significance:
Experimentally, the flexural modulus and thickness of resin-based material used to cement DBC or PLV restorations have a significant impact on the magnitude of resin-strengthening observed. However, for resin-based materials with different flexural moduli the variability in the relationships between thickness and observed increases in biaxial flexure strength of the ceramic requires careful characterization to optimize clinical performance.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Strain and Elastic Modulus
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...