Related Experiment Video
Updated: May 22, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Full automatic determination of chlorophenols in water using solid-phase microextraction/on-fiber derivatization and
Xiaowei Wang1, Ruohong Chen, Tiangang Luan
1MOE Key Laboratory of Aquatic Product Safety, School of Life Sciences, Sun Yat-sen University, Guangzhou, P R China.
Abstract:
A fully automated combination of solid-phase microextraction and on-fiber derivatization coupled with gas chromatography-mass spectrometry was developed to determine 17 chlorophenols in aqueous samples. Optimal parameters for the automated process, such as fiber coating (polyacrylate), derivatization reagent (N,O-bis(trimethylsilyl) trifluoroacetamide), extraction time (60 min), derivatization time (5 min), incubation temperature (35°C), sample pH (3), and ionic strength (300 g L(-1) of NaCl), as well as desorption time (5 min) and desorption temperature (270°C) were established. The whole procedure took only 90 min and was performed automatically. The shortcomings of silylation derivatives, like incompleteness and instability, were overcome by using solid-phase microextraction on-fiber silylation in this study. The results from both pure water and river water samples showed that the method had a good linearity (r(2) = 0.9993-1.0000), ranging from 0.01 to 100 μg L(-1). The related standard deviations were between 3.6 and 10.0%. The limits of detections and qualifications ranged from 0.03 to 3.11 ng L(-1) and 0.09 to 10.4 ng L(-1) for the CPs, respectively. The proposed method is superior to traditional solid phase extraction procedure.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.