Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Metrics of separation performance in chromatography: Part 2. Separation performance of a heating ramp in
1Fast GC Consulting, P.O. Box 1243, Wilmington, DE 19801, USA. leon@fastgc.com
Abstract:
Metrics of separation performance described in Part 1 of this series were applied here to theoretical evaluation of performance of a heating ramp in temperature-programmed GC. As in Part 1, the dependence of the separation (Δs) of two arbitrarily spaced peaks (the number of σ-slots between them) on operational parameters of GC analysis was treated here as the main building block for construction of other performance metrics. Simple expressions describing Δs of two peaks eluting during isobaric linear heating ramp and dependence of Δs on the heating rate, on column efficiency and on the peak spacing were derived. The use of dimensionless heating rate and other dimensionless operational parameters made these expressions universally suitable for different column dimensions, heating rates, carrier gas types, flow rates, etc. The use of dimensionless parameters also made it possible to express Δs as a simple function of the earlier introduced chromatographically meaningful characteristic parameters of thermodynamics of solute-column interactions. The expressions for Δs developed here, together with the ones described in Part 1 were used for theoretical prediction of total separation capacity (s(c)), total peak capacity (n(c)), and total number of resolved peaks in temperature-programmed analysis controlled by a balanced temperature program consisting of a linear heating ramp preceded by specially designed balanced temperature plateau. A numerical example of these parameters for a particular column, heating rate, carrier gas, and its flow rate is also provided. It has been shown that n(c) obtainable in temperature-programmed analysis is 2-3 times larger than that obtainable in equally long isothermal analysis using the same column and gas. Comparison of this improvement with potentially more than an order of magnitude larger peak capacity of GC×GC has been discussed. Also described are the speed of analysis (the number of σ-slots per unit of time), and other characteristics of the separation performance of a heating ramp. In many respects, metric Δs is similar to the widely known metric of resolution (R(s)). Advantages of Δs over R(s) as a metric of the separation performance, as well as the advantages of other metrics utilized here over their widely known counterparts are discussed.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Performance Liquid Chromatography: Elution Process