Obtaining reference intervals traceable to reference measurement systems: is it possible, who is responsible, what is
Mauro Panteghini1, Ferruccio Ceriotti
1Centro Interdipartimentale per la Riferibilità Metrologica in Medicina di Laboratorio (CIRME), Universit à degli Studi, Milano, Italy. mauro.panteghini@unimi.it
Abstract:
An issue associated with standardization efforts is the need to develop useful reference intervals (RI). Lack of proper RI may hamper the implementation of standardization in Laboratory Medicine as standardization can modify analyte results and, without adequate RI, this can impair the result interpretation. Once defined, RI obtained with analytical procedures that produce results traceable to the corresponding reference system can be transferred among laboratories, providing that they use commercial assays that produce results traceable to the same reference system and populations have the same characteristics. Multicenter studies are needed for a robust definition of traceable RI, using experimental protocols that include well defined prerequisites. Particularly, employed methods must produce results that are traceable to the reference system for that specific analyte. Thus, the trueness of laboratories producing reference values should be verified and, if necessary, experimental results corrected in accordance with correlation results with the selected reference. If requirements in the adoption of traceable RI are fulfilled, the possibility of providing RI that are applicable to any laboratory, able to produce results traceable to the reference system, is realistic. The definition of traceable RI should hopefully cause the disappearance of different RI employed for the same analyte, providing more effective information to clinicians.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Errors occurring during blood pressure monitoring
Several factors...
Uncertainty in Measurement: Accuracy and Precision
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Titrimetric Methods: Types and Commonly Used Strategies
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...