Background:
Lithium carbonate salt has become an increasingly important substance in the treatment of manic depressive disorders, and its relatively narrow therapeutic range has caused laboratories to monitor the serum concentration carefully. In the present work we evaluated lithium measurement in 3 different analyzers. METHODS #ENTITYSTARTX00026;
Materials:
Three different analyzers including Flame Emission (FES), Flame Atomic Absorption Spectroscopy (FAAS), and Ion Selective Electrode (ISE) were used. All chemicals had a grade suitable for trace metal analysis.
Results:
Within-day precision of CV was ≤ 1.5% for FES & FAAS, except for ISE (1.9% CV). Between-days precision of CV was less for FES than for FAAS and ISE (1.3% versus 2.2% & 2.3%). The percent recovery of added lithium in pooled patients' serum was higher for ISE than for FASS and FES (103.4% versus 96.2% and 94.6%). We also obtained a higher average lithium concentration for patients' serum samples (n=16) measured by ISE than for FAAS and FES (0.825±0.30 versus 0.704±0.26 & 0.735±0.19). Paired t-test results revealed a significant difference (p< 0.001) for patient sera analyzed with FAAS and ISE.
Conclusion:
We report higher results for ISE than the other two analyzers and conclude that the choice between the two flame methods for patients' serum lithium determination is arbitrary and that FES analyzer is a more attractive routine alternative for lithium determination than FAAS because of its cost and ease of performance. In addition, the results obtained by ISE are precise. However, its accuracy may depend on other interfering factors.
More Related Videos
10:41Three-electrode Coin Cell Preparation and Electrodeposition Analytics for Lithium-ion Batteries
Published on: May 22, 2018
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
Related Concept Videos
Flame Photometry: Lab
Atomic Emission Spectroscopy: Lab
Flame Photometry: Overview
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Interference
Atomic Emission Spectroscopy: Overview