The Ornstein-Uhlenbeck third-order Gaussian process (OUGP) applied directly to the un-resampled heart rate
A C Fisher1, A Eleuteri, D Groves
1Department of Medical Physics and Clinical Engineering, Royal Liverpool and Broadgreen University Hospital, Liverpool, UK. a.c.fisher@liv.ac.uk
Abstract:
The heart rate variability signal derived from the ECG is a beat-to-beat record of RR-intervals and is, as a time series, irregularly sampled. It is common engineering practice to resample this record, typically at 4 Hz, onto a regular time axis for conventional analysis using IIR and FIR filters, and power spectral estimators, in the time and frequency domain, respectively. However, such interpolative resampling introduces noise into the signal and the information quality is compromised. Here, the Ornstein-Uhlenbeck third-order band-pass filter is presented which operates on data sampled at arbitrary time and preserves fidelity. The algorithm is available as open source code for MATLAB(®) (MathWorks™ Inc.) and supported by an interactive website at http://clinengnhs.liv.ac.uk/OUGP.htm.
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...