Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
In-silico prediction of gas chromatographic retention indices of some terpenols
Mohammad H Fatemi1, Hanieh Malekzadeh
1Laboratory of Chemometrics, Faculty of Chemistry, University of Mazandaran, Babolsar, Iran. mhfatemi@umz.ac.ir
Abstract:
A quantitative structure-retention relationship study based on multiple linear regression technique was carried out to investigate the gas chromatographic retention indices (RIs) of some terpenols on the HP 5 ms fused silica column. A collection of 75 terpene alcohols was chosen as dataset. The data were divided into two groups; a training set and a prediction set consist of 60 and 15 molecules, respectively. The best-selected descriptors that appear in the models are; the Randic index order 1, Kier shape index order 2, total charge weighted partial negatively charged surface area, and fractional atomic charge weighted partial positive surface area. These descriptors can encode different features of molecules that are responsible for their steric, electronic, and lipophilicity interactions. The best-obtained model had statistics of R(2)(t) = 0.959 and R(2)(p) = 0.952. The reliability of the model was evaluated by using the leave-many-out cross-validation method (Q(2) = 0.957 and SPRESS = 46.427) as well as by y-scrambling and jackknife test. Furthermore, the chemical applicability domains of these models were determined via leverage approach. The simple developed four-parameter linear model can predict the gas chromatographic RIs of terpenols.
More Related Videos
08:42Infection of In Vivo and In Vitro Pines with the Pinewood Nematode Bursaphelenchus xylophilus and Isolation of Induced Volatiles
Published on: September 27, 2024
10:50Transcript and Metabolite Profiling for the Evaluation of Tobacco Tree and Poplar as Feedstock for the Bio-based Industry
Published on: May 16, 2014
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...