Related Experiment Video
Updated: May 20, 2026

Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
Capillary electrophoresis with capacitively coupled contactless conductivity detection: a universal tool for the
1Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic, vvi, Brno, Czech Republic. kuban@iach.cz
Abstract:
Monitoring the selectivity of supported liquid membranes (SLMs) is of paramount importance since the amount and type of compounds that are transferred across a SLM directly influence the transfer efficiency, reproducibility and accuracy. To apply a correct SLM in particular sample pretreatment, rapid determination of the transfer of analytes and matrix compounds across the SLM is necessary, which requires the use of an analytical method with universal detection technique. Capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C(4)D) has proven to be a useful tool for the determination of SLM selectivity. Background electrolyte solution consisting of 1M acetic acid (pH 2.4) was used for simultaneous separation and detection of three basic drugs (nortriptyline, haloperidol and loperamide) and major matrix components (inorganic cations, proteins, amino acids, etc.) after electromembrane extraction (EME) of standard solutions and complex samples. The CE-C(4)D method has evidenced for the first time that large proteins, such as human serum albumin, are efficiently retained on all examined SLMs and that transfer of other matrix components and the analytes is strongly SLM dependent. Excellent transfer of the analytes was achieved across SLMs impregnated with 2-nitrophenyl octyl ether (NPOE) or 1-ethyl-2-nitrobenzene, however, an increased co-extraction of interfering matrix components, which disabled quantitative determination of haloperidol with the current CE-C(4)D setup, was observed for the latter. After addition of a commonly used ion carrier (bis(2-ethylhexyl)phosphate) to NPOE, a wide range of matrix components were transferred across the SLM with no measurable transfer of the analytes. Best selectivity regarding transfer of the basic drugs and elimination of matrix components was obtained using SLM impregnated with NPOE. An optimized EME-CE-C(4)D method was used to determine the basic drugs in various samples and satisfactory analytical parameters were obtained.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Ion-Exchange Chromatography
Potentiometry: Membrane Electrodes
Interfacial Electrochemical Methods: Overview
