[Spectral characteristic of short-arc xenon lamp and application in solar simulators]
1Department of Thermal Science & Energy Engineering, University of Science & Technology of China, Hefei 230027, China. lq152618379@126.com
Abstract:
Due to the inhomogeneous spatial spectral distribution of short-arc xenon lamp, its application is difficult. In the present paper, axially spectral distribution of xenon lamp was measured and temperature distribution was calculated, the temperature distribution was analysed as exponential relationship with arc current density. Therefore, xenon lamp spectral distribution can be made closer to the standard solar simulator spectral distribution by controlling current density.
More Related Videos
Related Concept Videos
UV–Vis Spectrometers
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Fluorescence and Phosphorescence: Instrumentation