Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Specific absorption rate evaluation for passengers using wireless communication devices inside vehicles with
Sai-Wing Leung1, Yinliang Diao, Kwok-Hung Chan
1Department of Electronic Engineering, City University of Hong Kong, Kowloon, Hong Kong. eeswl@cityu.edu.hk
Abstract:
Radiation from mobile phones inside vehicles, which are semiopen metallic enclosures with irregular shapes and apertures, has been a major concern and has warranted investigation in past years. In this paper, the specific absorption rate (SAR) induced in mobile phone users inside a vehicle was evaluated using different scenarios, including handedness, passenger counts, and seating locations. A computer simulation for SAR distributions in a human body was performed based on the finite-difference time-domain method. The SAR values in mobile phone users in free space were also compared to those inside a vehicle; results illustrated that the maximum SAR induced for mobile phone users in a vehicle is 5% higher than those in free space, but the SAR results showed no significant difference for the handedness. By comparing the SAR values between mobile phone users and nonusers inside a vehicle with a passenger count and seating locations, it was observed that the SAR values around the nonusers' body varied much in different situations, and were higher than those in free space, in some circumstances.
Related Concept Videos
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...