Related Experiment Video
Updated: May 19, 2026

Isolation and Identification of Waterborne Antibiotic-Resistant Bacteria and Molecular Characterization of their Antibiotic Resistance Genes
Published on: March 3, 2023
Inter-laboratory exercise on antibiotic drugs analysis in aqueous samples
1Environment and Health Research laboratory (LERES), Advanced School of Public Health (EHESP), Avenue du Professeur Léon Bernard-CS 74312, 35043 Rennes Cedex, France. benoit.roig@ehesp.fr
This European inter-laboratory exercise evaluated antibiotic measurement methods in surface and tap water. Results showed variability but confirmed sample stability, guiding future water quality assessments.
Area of Science:
- Environmental Chemistry
- Analytical Chemistry
- Public Health
Background:
- Antibiotic contamination in water poses a significant public health risk.
- Standardized analytical methods are crucial for accurate monitoring of pharmaceutical residues in aquatic environments.
- The PHARMAS EU project aimed to address the need for reliable antibiotic detection in water.
Purpose of the Study:
- To evaluate the performance of diverse analytical methods for antibiotic quantification in surface and tap water.
- To assess the variability of results obtained from multiple laboratories across different countries.
- To determine the success rate of participating laboratories in an inter-laboratory testing exercise.
Main Methods:
- An inter-laboratory exercise involving thirteen laboratories from five European countries and Canada.
- Distribution of spiked tap and river water samples for antibiotic analysis over one month.
- Statistical analysis of 611 results, including calculation of mean, standard deviation, median, and outlier detection.
Main Results:
- Seventy-seven out of seventy-eight (98.7%) testing samples were analyzed, yielding 305 values in duplicate.
- Outlier results constituted 6% of the accounted values and were excluded from further analysis.
- Evaluation of sample stability showed no representative variations, indicating consistent sample integrity throughout the exercise.
Conclusions:
- The inter-laboratory exercise successfully assessed result variability and the influence of different water matrices on antibiotic analysis.
- Participating laboratories demonstrated a high rate of successful test completion, validating the developed methodologies.
- This study provides valuable insights into the performance of analytical methods for environmental antibiotic monitoring in Europe.
More Related Videos
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018