Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Comparison of non-invasive and invasive blood pressure in aeromedical care
N McMahon1, L A Hogg, A R Corfield
1Emergency Medical Retrieval Service, Glasgow, UK.
Abstract:
Blood pressure measurement is an essential physiological measurement for all critically ill patients. Previous work has shown that non-invasive blood pressure is not an accurate reflection of invasive blood pressure measurement. In a transport environment, the effects of motion and vibration may make non-invasive blood pressure less accurate. Consecutive critically ill patients transported by a dedicated aeromedical retrieval and critical care transfer service with simultaneous invasive and non-invasive blood pressure measurements were analysed. Two sets of measurements were recorded, first in a hospital environment before departure (pre-flight) and a second during aeromedical transport (in-flight). A total of 56 complete sets of data were analysed. Bland-Altman plots showed limits of agreement (precision) for pre-flight systolic blood pressure were -37.3 mmHg to 30.0 mmHg, and for pre-flight mean arterial pressure -20.5 mmHg to 25.0 mmHg. The limits of agreement for in-flight systolic blood pressure were -40.6 mmHg to 33.1 mmHg, while those for in-flight mean blood pressure in-flight were -23.6 mmHg to 24.6 mmHg. The bias for the four conditions ranged from 0.5 to -3.8 mmHg. There were no significant differences in values between pre-flight and in-flight blood pressure measurements for all categories of blood pressure measurement. Thus, our data show that non-invasive blood pressure is not a precise reflection of invasive intra-arterial blood pressure. Mean blood pressure measured non-invasively may be a better marker of invasive blood pressure than systolic blood pressure. Our data show no evidence of non-invasive blood pressures being less accurate in an aeromedical transport environment.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure