Enhanced cascade control for a class of integrating processes with time delay.
Dola Gobinda Padhan1, Somanath Majhi
1Department of Electronics and Electrical Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India. dola@iitg.ernet.in
A new series cascade control strategy improves performance for integrating processes with time delays. This method uses two controllers and a setpoint filter for enhanced closed-loop control and disturbance rejection.
Area of Science:
- Process Control
- Control Engineering
- Automation Systems
Background:
- Cascade control strategies are limited for integrating processes with time delays.
- Enhancing closed-loop performance in such systems is a significant challenge.
Purpose of the Study:
- To propose a novel series cascade control structure for integrating processes with time delay.
- To improve closed-loop performance and disturbance rejection capabilities.
Main Methods:
- The proposed structure utilizes two controllers and a setpoint filter.
- Inner loop controller designed using the Internal Model Control (IMC) approach.
- Primary load disturbance rejection controller designed using a PID controller in series with a lead/lag compensator, based on desired closed-loop complementary sensitivity function.
- Robustness analysis performed using Kharitonov's theorem.
Main Results:
- Simulation results demonstrate the efficacy of the proposed control structure.
- Satisfactory nominal performance achieved for integrating processes with time delay.
- Robust performance demonstrated under various conditions.
Conclusions:
- The novel series cascade control structure effectively enhances closed-loop performance for integrating processes with time delay.
- The proposed method offers a viable solution for challenging control problems in industrial processes.
- The controller design and robustness analysis provide a solid foundation for practical implementation.
Related Concept Videos
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Phase-lead and Phase-lag Controllers
Classification of Systems-II
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...