Updated: May 18, 2026

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

Hydrodynamic resettability for a microfluidic particulate-based arraying system.

Ryan D Sochol1, Megan E Dueck, Song Li

  • 1Department of Mechanical Engineering, University of California, Berkeley, USA. rsochol@gmail.com

Lab on a Chip
|October 9, 2012
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Author Correction: Acoustic metamaterials-driven transdermal drug delivery for rapid and on-demand management of acute disease.

Nature communications·2026
Same author

Interfacial and structural optimization of graphene wrapped β-MnO<sub>2</sub> nanorod cathodes for long-life aqueous zinc-ion batteries.

Journal of colloid and interface science·2026
Same author

Integrated microfluidic biosensors: shaping the future of quantitative life sciences and on-chip molecular diagnostics.

Lab on a chip·2026
Same author

Tailored-Reflectivity Microstructures for Measuring Signal Sensitivity of Optical Coherence Tomography Medical Imaging Systems.

Advanced materials technologies·2026
Same author

Transport of enzymatic activity across liquid-liquid interfaces using dynamic assemblies of magnetic particles via field-modulated interactions.

Nature communications·2026
Same author

Direct laser writing of a titanium dioxide-laden retinal cone phantom for adaptive optics-optical coherence tomography.

Optical materials express·2026
Same journal

Microfluidic rare cell analysis beyond counting: workflow design from enrichment to multi-omics.

Lab on a chip·2026
Same journal

A sperm racetrack to separate sperm by swim speed.

Lab on a chip·2026
Same journal

Controlled encapsulation and droplet size prediction in two-step microfluidic double emulsions.

Lab on a chip·2026
Same journal

A particulate blood-mimicking fluid with physiological biconcave geometry for microscale hemorheology.

Lab on a chip·2026
Same journal

Multicellular sensor arrays fabricated by capillary stamping for pattern-based odor discrimination.

Lab on a chip·2026
Same journal

A real-time microfluidic surveillance system for multiplex detection of heavy metal contamination in wastewater.

Lab on a chip·2026
See all related articles

A new single-layer hydrodynamic method enables resettable microfluidic arrays for high-efficiency microparticle and cell trapping. This breakthrough allows for 100% recovery and array reusability in lab-on-a-chip systems.

Area of Science:

  • Microfluidics
  • Biotechnology
  • Materials Science

Background:

  • Microfluidic particulate-based arraying is crucial for lab-on-a-chip applications.
  • Achieving full microarray resettability without compromising trapping performance is a significant challenge.

Purpose of the Study:

  • To develop a single-layer hydrodynamic method for releasing microparticles after microfluidic arraying.
  • To demonstrate high trapping and resetting efficiencies for both microbeads and cells.

Main Methods:

  • Utilized a single-layer hydrodynamic technique for microparticle manipulation.
  • Conducted experiments with streptavidin-coated polystyrene microbeads (15 μm) and endothelial cells (13-17 μm).
  • Assessed trapping, loading, and resetting efficiencies.

More Related Videos

A Microfluidic-based Hydrodynamic Trap for Single Particles
10:13

A Microfluidic-based Hydrodynamic Trap for Single Particles

Published on: January 21, 2011

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration
08:43

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration

Published on: February 1, 2022

Related Experiment Videos

Last Updated: May 18, 2026

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

A Microfluidic-based Hydrodynamic Trap for Single Particles
10:13

A Microfluidic-based Hydrodynamic Trap for Single Particles

Published on: January 21, 2011

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration
08:43

Pneumatically Driven Microfluidic Platform for Micro-Particle Concentration

Published on: February 1, 2022

Main Results:

  • Achieved 100% resetting efficiency for microbeads, with 99% trapping and 99.8% loading efficiency.
  • Demonstrated high trapping efficiencies for endothelial cells (65% for single cell, 93% for at least one cell per trap) with 78% loading efficiency.
  • Confirmed full cell-based resettability with appropriate reagents.

Conclusions:

  • The presented resettable microarray method effectively releases high numbers of microparticles.
  • This technology enhances lab-on-a-chip platforms by enabling microparticle retrieval and microarray reusability.
  • The method is adaptable for both bead-based and cell-based microfluidic applications.