Related Experiment Video
Updated: May 17, 2026

Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Pulmonary vein isolation using a single size cryoballoon chosen according to transesophageal echocardiography
Michaël Peyrol1, Pascal Sbragia, Amandine Quatre
1Division of Cardiology, Hôpital Nord, Aix-Marseille Université, Marseille, France. michael.peyrol@ap-hm.fr
Background:
Pulmonary vein isolation (PVI) using cryoballoon (CB) catheter is a new technique for atrial fibrillation (AF) ablation. Previous studies used computer tomography (CT) or magnetic resonance imaging (MRI) scan to determine the pulmonary vein (PV) diameter and anatomy for choosing the CB size. We evaluated pre-ablation transoesophageal-echocardiography (TEE) as an alternative to CT/MRI scan in patients undergoing AF ablation for determining the appropriate size of the CB.
Methods:
Fifty-five consecutive patients (men=43, women=12) with a mean age of 63 ± 12.5 years, and with drug-refractory paroxysmal AF (34 patients) or persistent AF (21 patients) were included in this prospective study. All patients underwent pre-ablation TEE.
Results:
Hypertension was present in 19 patients (34%). Mean anterior-posterior left atrium diameter was 45.1 ± 8.9 mm. In total, 217 PV were targeted using a single 23-mm (n=14) or 28-mm (n=40) CB catheter chosen according to TEE-obtained measurements. PVI was achieved in 195 PV (90%). Mean number of CB applications per patient was 9.8 ± 2.1 (range 8-14). Mean procedure duration and fluoroscopy times were 131 ± 27 min (90-190 min) and 36 ± 12 min (22-66 min) respectively. Phrenic nerve palsy occurred in 3 patients (5.4%) and was transient (<1 month) in all of them.
Conclusion:
This study suggests that TEE is an easily available and effective tool to select the size of the CB for PVI according to evaluated PV diameters and anatomy.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care