Related Experiment Video
Updated: May 17, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Quantitative visually lossless compression ratio determination of JPEG2000 in digitized mammograms
Verislav T Georgiev1, Anna N Karahaliou, Spyros G Skiadopoulos
1Department of Medical Physics, Faculty of Medicine, University of Patras, 26504, Patras, Greece.
Abstract:
The current study presents a quantitative approach towards visually lossless compression ratio (CR) threshold determination of JPEG2000 in digitized mammograms. This is achieved by identifying quantitative image quality metrics that reflect radiologists' visual perception in distinguishing between original and wavelet-compressed mammographic regions of interest containing microcalcification clusters (MCs) and normal parenchyma, originating from 68 images from the Digital Database for Screening Mammography. Specifically, image quality of wavelet-compressed mammograms (CRs, 10:1, 25:1, 40:1, 70:1, 100:1) is evaluated quantitatively by means of eight image quality metrics of different computational principles and qualitatively by three radiologists employing a five-point rating scale. The accuracy of the objective metrics is investigated in terms of (1) their correlation (r) with qualitative assessment and (2) ROC analysis (A z index), employing pooled radiologists' rating scores as ground truth. The quantitative metrics mean square error, mean absolute error, peak signal-to-noise ratio, and structural similarity demonstrated strong correlation with pooled radiologists' ratings (r, 0.825, 0.823, -0.825, and -0.826, respectively) and the highest area under ROC curve (A z , 0.922, 0.920, 0.922, and 0.922, respectively). For each quantitative metric, the highest accuracy values of corresponding ROC curves were used to define metric cut-off values. The metrics cut-off values were subsequently used to suggest a visually lossless CR threshold, estimated to be between 25:1 and 40:1 for the dataset analyzed. Results indicate the potential of the quantitative metrics approach in predicting visually lossless CRs in case of MCs in mammography.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Ultrasonography

