Physical, chemical and microbial analysis of bottled drinking water
S Sasikaran1, K Sritharan, S Balakumar
1Department of Agricultural Chemistry, Faculty of Agriculture, University of Jaffna, Sri Lanka. sasit_agri@yahoo.com
Introduction:
People rely on the quality of the bottled drinking water, expecting it to be free of microbial contamination and health hazards.
Objectives:
To evaluate the quality of bottled drinking water sold in Jaffna peninsula by analysing the physical, chemical and microbial contents and comparing with the recommended Sri Lankan Standard (SLS) values.
Methods:
All bottled water samples sold in Jaffna peninsula were collected. Electrical conductivity, total dissolved solid, pH, calcium, nitrate, total aerobic and anaerobic count, coliform bacterial count and faecal contamination were checked.
Results:
These are 22 brands of bottled drinking water sold in Jaffna peninsula. The sample had very low electrical conductivity when compared with SLS (750 μS/ cm) and varied from 19 to 253 μS/cm with the mean of 80.53 (±60.92) μS/cm. The pH values of the bottled drinking water brands varied from 4.11 to 7.58 with a mean of 6.2 (±0.75). The total dissolved solid content of the bottled drinking water brands varied from 9 to 123.67 mg/l with a mean of 39.5 (±30.23) mg/l. The calcium content of the bottled drinking water brands varied from 6.48 to 83.77 mg/l with a mean of 49.9 (±25.09) mg/l. The nitrate content of the bottled drinking water brands varied from 0.21 to 4.19 mg/l with the mean of 1.26 (±1.08) mg/l. Aerobic bacterial count varied from 0 to 800 colony forming unit per ml (cfu/ml) with a mean of 262.6 (±327.50) cfu/ml. Among the 22 drinking bottled water brands 14 and 9% of bottled drinking water brands showed fungal and coliform bacterial contaminants respectively. The water brands which contained faecal contamination had either Escherichia coli or Klebsiella spp.
Conclusions:
The bottled drinking water available for sale do not meet the standards stipulated by SLS.
More Related Videos
09:10Multimodal Analysis of Microplastics in Drinking Water using a Silicon Nanomembrane Analysis Pipeline
Published on: June 13, 2025
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
Related Concept Videos
Precipitation and Co-precipitation
Development of Analytical Methods
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
pH
Automated Microbial Diagnostics