Nine-Grid Area Division Method: A New Ideal Bone Puncture Region for Percutaneous Vertebroplasty in Lumbar Spine
Published on: August 9, 2024
Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique
Yen-Yao Li1, Tsung-Jen Huang, Chin-Chang Cheng
1Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Chiayi, No6 W Sec, Chia-pu Rd, Putz City, Chiayi County, 613, Taiwan. orthoyao@cgmh.org.tw
The two-fluoroscopic technique in percutaneous vertebroplasty (PV) significantly reduces patient radiation exposure and operative time compared to the one-fluoroscopic technique. Operator radiation exposure remained similar between the two methods.
Area of Science:
- Interventional Radiology
- Medical Physics
- Surgical Techniques
Background:
- Percutaneous vertebroplasty (PV) traditionally involves lengthy fluoroscopic guidance, leading to significant radiation exposure.
- The two-fluoroscopic technique offers simultaneous two-planar imaging, potentially reducing procedure time.
- Concerns exist regarding increased radiation doses with the two-fluoroscopic technique.
Purpose of the Study:
- To quantify and compare patient and operator radiation exposure during PV using one- vs. two-fluoroscopic techniques.
- To evaluate the impact of the two-fluoroscopic technique on operative time.
Main Methods:
- A comparative study involving 26 single-level PV procedures.
- Radiation doses measured using dosimeters on patients and operators.
- Procedures were allocated to either one-fluoroscopic (13 patients) or two-fluoroscopic (13 patients) technique groups.
Main Results:
- The two-fluoroscopic technique group showed significantly lower mean patient radiation dose (0.95 mSv) compared to the one-fluoroscopic group (1.97 mSv) (P=0.031).
- Mean operator radiation dose was comparable between the one-fluoroscopic (0.27 mSv) and two-fluoroscopic (0.25 mSv) groups (P=0.653).
- Operative time was significantly reduced with the two-fluoroscopic technique (36.62 min) versus the one-fluoroscopic technique (47.15 min) (P=0.019).
Conclusions:
- The two-fluoroscopic technique in PV is associated with reduced patient radiation exposure.
- Shorter operative times were achieved using the two-fluoroscopic technique.
- Operator radiation exposure did not differ significantly between the one- and two-fluoroscopic techniques.