Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Two-Dimensional Microscopy in Microbiology01:29

Two-Dimensional Microscopy in Microbiology

Two-dimensional (2D) microscopy encompasses a range of optical techniques that capture images within a single focal plane, offering detailed representations of microscopic structures. These techniques are essential in biological and medical research, enabling the visualization of cellular and subcellular structures with different levels of contrast and specificity.There are several major types of 2D microscopy, each with strengths and applications.Bright-Field MicroscopyBright-field microscopy...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Exposure control at the first dark-field chest radiography demonstrator system.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2025
Same author

Finite element fracture load analysis and dark-field X-ray imaging of osteoporotic and healthy vertebrae in human lumbar spine specimens.

BMC musculoskeletal disorders·2025
Same author

Parity-dependent state transfer for direct entanglement generation.

Nature communications·2025
Same author

[Plaque characterization and individualized risk assessment].

Radiologie (Heidelberg, Germany)·2024
Same author

[Imaging of neuroendocrine tumors of the gastrointestinal tract : Value of (hybrid) imaging diagnostics in radiology].

Radiologie (Heidelberg, Germany)·2024
Same author

ForMAX - a beamline for multiscale and multimodal structural characterization of hierarchical materials.

Journal of synchrotron radiation·2024

Related Experiment Video

Updated: May 14, 2026

Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release
06:02

Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release

Published on: June 12, 2021

Microbubbles as a scattering contrast agent for grating-based x-ray dark-field imaging.

A Velroyen1, M Bech, A Malecki

  • 1Department of Physics and Institute of Medical Engineering, Technische Universität München, James-Franck-Straße, D-85748 Garching, Germany. astrid.velroyen@tum.de

Physics in Medicine and Biology
|February 2, 2013
PubMed
Summary

This study explores using ultrasound microbubbles as a new type of contrast agent for advanced X-ray dark-field imaging. Unlike traditional iodine-based agents, these bubbles are safe for patients with kidney or thyroid issues. The researchers demonstrate that these bubbles significantly improve image quality in dark-field X-ray scans, even when using standard clinical equipment.

Keywords:
X-ray scatteringcontrast enhancementdiagnostic radiologymedical physics

Frequently Asked Questions

More Related Videos

Imaging and Quantification of the Area of Fast-Moving Microbubbles Using a High-Speed Camera and Image Analysis
05:31

Imaging and Quantification of the Area of Fast-Moving Microbubbles Using a High-Speed Camera and Image Analysis

Published on: September 5, 2020

Related Experiment Videos

Last Updated: May 14, 2026

Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release
06:02

Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release

Published on: June 12, 2021

Imaging and Quantification of the Area of Fast-Moving Microbubbles Using a High-Speed Camera and Image Analysis
05:31

Imaging and Quantification of the Area of Fast-Moving Microbubbles Using a High-Speed Camera and Image Analysis

Published on: September 5, 2020

Area of Science:

  • Medical imaging physics within diagnostic radiology
  • Microbubbles as a scattering contrast agent for advanced imaging modalities
  • Radiological physics and instrumentation research

Background:

Standard medical X-ray imaging relies heavily on iodine-based agents to improve visibility of internal structures. These traditional substances often pose significant risks for individuals suffering from pre-existing renal failure or thyroid complications. No prior work had resolved how to safely utilize alternative materials for contrast enhancement in emerging X-ray modalities. That uncertainty drove interest in exploring substances already approved for clinical ultrasound applications. Dark-field imaging represents a novel approach that captures information beyond simple attenuation patterns. This technique specifically measures ultra-small-angle coherent scattering to generate unique diagnostic data. Prior research has shown that grating-based setups can successfully acquire these signals alongside conventional images. This gap motivated the current investigation into whether microbubbles could serve as effective scattering agents for this specific imaging method.

Purpose Of The Study:

The researchers aim to evaluate the feasibility of using microbubbles as a scattering contrast agent for grating-based X-ray dark-field imaging. This work addresses the need for alternative contrast media that avoid the risks associated with iodine-based substances. Traditional agents are often contraindicated for patients with pre-existing renal impairment or thyroid dysfunction. The study investigates whether ultrasound contrast agents can provide sufficient scattering signals for dark-field modalities. By exploiting ultra-small-angle coherent X-ray scattering, the team seeks to generate enhanced image contrast. The investigation focuses on demonstrating that this method works effectively with standard X-ray tube-based hardware. The authors also intend to assess how detector pixel size influences the relative contrast gain of the scattering signal. This effort seeks to validate the clinical utility of the approach at standard diagnostic resolutions.

Main Methods:

The investigators employed a grating-based X-ray imaging architecture to evaluate the scattering potential of the contrast media. This design allowed for the simultaneous collection of attenuation, phase-contrast, and dark-field data streams. The team utilized ultrasound-approved gas-filled spheres as the primary scattering target for these experiments. The experimental approach involved testing the signal response across a range of detector resolutions. Researchers specifically compared the performance of the scattering signal against traditional absorption-based metrics. The study utilized an X-ray tube source to ensure the findings remained applicable to standard clinical hardware. Data analysis focused on calculating the contrast-to-noise ratio at different pixel dimensions. This systematic evaluation confirmed the efficacy of the scattering agents under various imaging conditions.

Main Results:

The study demonstrates that microbubbles produce strongly enhanced dark-field contrast compared to traditional attenuation signals. This enhancement provides a superior contrast-to-noise ratio for visualizing structures within the imaging field. The researchers show that the method functions effectively when utilizing a standard X-ray tube-based setup. The relative contrast gain exhibits a positive trend as the pixel size increases from tenths of microns. This improvement continues up to detector resolutions of approximately one millimetre. These results confirm that the technique maintains high performance at clinically compatible imaging scales. The scattering signal remains robust across these different spatial resolutions during the experimental trials. This performance indicates that the approach is well-suited for integration into existing medical diagnostic workflows.

Conclusions:

The researchers propose that microbubbles serve as highly effective scattering agents for grating-based dark-field X-ray imaging. This approach offers a viable alternative for patients who cannot tolerate traditional iodine-based contrast media. The study demonstrates that dark-field signals provide a superior contrast-to-noise ratio compared to standard attenuation-based methods. These findings suggest that the technique remains robust even when implemented using standard X-ray tube configurations. The authors highlight that the relative contrast gain improves as detector pixel sizes increase toward clinically relevant dimensions. This observation indicates strong potential for translating the method into practical medical environments. The team confirms that the scattering properties of these bubbles allow for high-quality imaging at resolutions compatible with current clinical standards. Future clinical implementation may benefit from the safety profile of these ultrasound-approved agents in diverse patient populations.

The researchers propose that microbubbles generate contrast through ultra-small-angle coherent X-ray scattering. This mechanism allows the dark-field signal to surpass the performance of traditional attenuation-based imaging in terms of contrast-to-noise ratios.

The team utilizes a grating-based X-ray imaging setup. This specialized hardware enables the simultaneous acquisition of refraction-based differential phase-contrast, conventional attenuation, and the dark-field scattering signals.

An X-ray tube-based setup is necessary to demonstrate the feasibility of this method in clinical environments. This configuration proves that the technique does not rely exclusively on highly specialized synchrotron radiation sources.

The authors utilize microbubbles, which are established ultrasound contrast agents. These gas-filled spheres provide the necessary scattering interface to produce dark-field signals, unlike iodine-based agents that rely on high atomic numbers for absorption.

The researchers measure the contrast-to-noise ratio across varying pixel sizes. They observe that the relative contrast gain increases as the resolution shifts from tenths of microns toward a millimetre.

The authors imply that this method provides a safer diagnostic option for patients with renal impairment or thyroid dysfunction. These individuals often face contraindications when receiving traditional iodine-based contrast media.