Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
Imaging Studies for Cardiovascular System II:Types of Echocardiography01:20

Imaging Studies for Cardiovascular System II:Types of Echocardiography

Echocardiography plays a role in assessing cardiac health and detecting heart conditions, with various types providing critical insights for diagnosis and treatment.
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
X-ray Imaging01:24

X-ray Imaging

German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An evaluation of brain volume and cortical thickness measurement at 0.55 T.

Magma (New York, N.Y.)·2026
Same author

Sex-related structural alterations across common epilepsies: a worldwide ENIGMA study.

bioRxiv : the preprint server for biology·2026
Same author

Imaging Near Spinal Fixation Hardware at 0.55 T Compared With 3 T.

Journal of magnetic resonance imaging : JMRI·2026
Same author

Population-based Brain Templates for Ultra-Low-Field MRI.

Scientific data·2026
Same author

Toxoplasma gondii infection is associated with changes in chronic outcomes in traumatic brain injury.

Translational psychiatry·2026
Same author

Diagnostic Accuracy of Plasma Biomarkers for Mild Traumatic Brain Injury in Older Adults.

JAMA network open·2026
Same journal

Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.

Magnetic resonance in medicine·2026
Same journal

A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp-Logan.

Magnetic resonance in medicine·2026
Same journal

7T 3D-EPI PCASL With High SNR Efficiency and Robustness to Through-Plane B<sub>0</sub> Field Gradients.

Magnetic resonance in medicine·2026
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
See all related articles

Related Experiment Video

Updated: May 13, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

Highly accelerated dynamic contrast enhanced imaging.

Robert Marc Lebel1, Jesse Jones, Jean-Christophe Ferre

  • 1Ming Hsieh Department of Electrical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA.

Magnetic Resonance in Medicine
|March 19, 2013
PubMed
Summary
This summary is machine-generated.

This article introduces a new magnetic resonance imaging technique that speeds up data collection significantly. By using advanced mathematical sampling and reconstruction methods, the researchers can capture high-resolution images of the entire brain quickly. This allows doctors to better measure blood vessel leakage and improve how they diagnose and monitor various diseases.

Keywords:
compressed sensingparallel imagingpermeability modelingspatial resolutiontemporal resolution

Frequently Asked Questions

More Related Videos

Contrast Enhanced Vessel Imaging using MicroCT
05:50

Contrast Enhanced Vessel Imaging using MicroCT

Published on: January 27, 2011

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
06:24

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model

Published on: April 18, 2015

Related Experiment Videos

Last Updated: May 13, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

Contrast Enhanced Vessel Imaging using MicroCT
05:50

Contrast Enhanced Vessel Imaging using MicroCT

Published on: January 27, 2011

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model
06:24

Dynamic Contrast Enhanced Magnetic Resonance Imaging of an Orthotopic Pancreatic Cancer Mouse Model

Published on: April 18, 2015

Area of Science:

  • Medical imaging physics and diagnostic radiology
  • Computational science in highly accelerated dynamic contrast enhanced imaging research

Background:

Standard medical imaging often struggles to balance speed with image detail. Current techniques frequently fail to capture the full scope of complex physiological processes. This limitation prevents clinicians from observing entire disease regions during a single scan. Furthermore, existing protocols cannot reliably track the rapid entry of contrast agents into tissues. That uncertainty drove the development of faster acquisition strategies. Prior research has shown that traditional methods lack the necessary temporal resolution for precise modeling. No prior work had resolved the trade-off between spatial coverage and scan duration effectively. This gap motivated the exploration of advanced mathematical frameworks to overcome these hardware constraints.

Purpose Of The Study:

The aim of this study is to present a method for highly accelerated dynamic imaging. This work addresses the limitations of current acquisition protocols regarding spatial and temporal resolution. The researchers seek to enable the characterization of entire pathologies within a single scan. They also intend to facilitate the measurement of the arterial input function, which is often precluded by slow imaging. This investigation explores whether advanced sampling schemes can overcome existing hardware-related bottlenecks. The authors hypothesize that combining specific sampling patterns with reconstruction constraints will improve diagnostic utility. They motivate this research by highlighting the need for better physiological information in clinical settings. This study provides a framework to enhance the management of various diseases through faster, more detailed imaging.

Main Methods:

The investigators developed a novel Poisson ellipsoid sampling scheme for data acquisition. They enforced multiple spatial and temporal l1-norm constraints during the image reconstruction process. The team conducted both retrospective and prospective analyses to verify their mathematical model. They tested acceleration rates ranging from 3× to 18× in the retrospective phase. Prospective trials utilized a 36× acceleration factor to capture brain volumes. The researchers compared their reconstructed outputs against standard clinical population metrics. They evaluated the performance by measuring errors in endothelial permeability values. This review approach confirms the reliability of the proposed reconstruction framework across different acceleration settings.

Main Results:

The researchers achieved a 36× acceleration rate in prospective brain imaging trials. This approach provided a spatial resolution of 0.94 × 0.94 × 1.9 mm(3) and a temporal resolution of 4.1 s. Retrospective testing showed less than 10% error in permeability measurements across all tested rates. No mean bias or diverging trends appeared when increasing acceleration from 3× to 18×. The reconstructed images displayed no visible degradation compared to standard clinical scans. These findings confirm that the method maintains high accuracy for physiological modeling. The data demonstrate that full brain coverage is feasible with this accelerated protocol. The results indicate that compressed sensing and parallel imaging effectively support high-resolution diagnostic imaging.

Conclusions:

The authors propose that their novel sampling scheme enables robust physiological modeling. Their results suggest that high acceleration rates do not compromise the accuracy of permeability measurements. This synthesis indicates that compressed sensing can successfully replace traditional, slower imaging workflows. The researchers conclude that full brain coverage is achievable without visible loss of image quality. Their findings imply that clinicians may soon obtain more comprehensive diagnostic data in less time. The study demonstrates that parallel imaging integration further enhances the reliability of the reconstructed data. These implications highlight a shift toward more efficient and detailed clinical assessments. Future applications might leverage these techniques to improve patient management across various pathological conditions.

The researchers utilize a Poisson ellipsoid sampling pattern combined with multiple spatial and temporal l1-norm constraints. This mathematical framework allows for the reconstruction of high-quality images from significantly undersampled data, enabling faster acquisition speeds while maintaining diagnostic precision.

The study employs compressed sensing, a signal processing technique that reconstructs sparse data, alongside parallel imaging, which uses multiple receiver coils to speed up acquisition. These tools work together to minimize artifacts while maintaining high spatial and temporal resolution.

A high acceleration rate is necessary to capture the rapid kinetics of contrast agents throughout the entire brain. Without this speed, the temporal resolution would be insufficient to measure the arterial input function accurately, which is vital for calculating endothelial permeability.

The authors use prospective and retrospective data to validate their approach. Retrospective analysis tests the algorithm against existing datasets, while prospective imaging applies the method in real-time to confirm that the 36× acceleration rate provides accurate, high-resolution brain scans.

The researchers measure endothelial permeability, represented as K(trans). They compare these values against a standard clinical population to ensure that the accelerated images provide physiologically accurate information despite the significant reduction in data collection time.

The authors propose that this method enables full brain, high-resolution acquisitions that were previously unattainable. They claim this advancement will improve the diagnosis and management of multiple pathologies by providing more complete physiological information than standard, slower imaging techniques.