Background:
Optimal femoral component rotational alignment in total knee arthroplasty (TKA) is crucial to establish a balanced knee reconstruction. Unbalanced knees can lead to instability, patellofemoral problems, persistent pain, stiffness, and generally poorer outcomes including early failure. Intraoperative techniques to achieve this optimal femoral component rotation include the use of the transepicondylar axis (TEA), the posterior-condylar-cut-parallel-to-the-tibial-cut (PCCPTC) technique and the anteroposterior axis technique (Whiteside's line). The purpose of this study was to compare the PCCPTC technique to the TEA technique using computed tomography (CT) scans to assess femoral component rotational alignment.
Materials And Methods:
This study used postoperative CT scans to compare the degree of femoral component rotation obtained with the use of PCCPTC technique and the TEA. The femoral component rotation of 30 TKA was measured on postoperative CT scans the angle of deviation between the two lines radiographic trans-epicondylar axis (rTEA) and femoral prosthesis posterior condylar line (FPPCL) was determined. This angle represented the rotation of the femoral component relative to the true rTEA.
Results:
The degree of rotation measured 2.67 ± 1.11 degrees in the PCCPTC group and 5.60 ± 1.64 degrees in the TEA group.
Conclusion:
The use of the TEA technique for determining rotational alignment in TKR results in excessive external rotation of the femoral component compared to the PCCPTC technique.
More Related Videos
08:15Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
06:28Anterior Cruciate Ligament Transection and Synovial Fluid Lavage in a Rodent Model to Study Joint Inflammation and Posttraumatic Osteoarthritis
Published on: September 2, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris group...