Mechanisms of endospore inactivation under high pressure
Kai Reineke1, Alexander Mathys, Volker Heinz
1Department of Food Biotechnology and Food Process Engineering, Technische Universitaet Berlin, Berlin, Germany. kreineke@atb-potsdam.de
Abstract:
It is well known that spore germination and inactivation can be achieved within a broad temperature and pressure range. The existing literature, however, reports contradictory results concerning the effectiveness of different pressure-temperature combinations and the underlying inactivation mechanism(s). Much of the published kinetic data are prone to error as a result of unstable process conditions or an incomplete investigation of the entire inactivation pathway. Here, we review this field of research, and also discuss an inactivation mechanism of at least two steps and propose an inactivation model based on current data. Further, spore resistance properties and matrix interactions are linked to spore inactivation effectiveness.
Related Concept Videos
Endospores and Sporulation
Gene Regulation During Sporulation
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Other Stress Responses in Bacteria
Methods of Sterilization II: Chemical Methods