Related Experiment Video
Updated: May 12, 2026

Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads
Published on: June 28, 2024
A highly sensitive differential pulse anodic stripping voltammetry for determination of 17β-estradiol (E2) using CdSe
Nuanapa Chaisuwan1, He Xu, Genying Wu
1College of Environmental Science and Engineering, Donghua University, Shanghai 201620, PR China.
Abstract:
In this study a new and fast procedure was developed to determine trace 17β-estradiol (E2) concentrations using CdSe quantum dots (QDs) conjugation with bovine serum albumin (BSA)-E2. To increase the high efficiency of the method, the immunoassay design was restricted to an indirect competitive format. The E2 antigen and bioconjugate were incubated in a microtiter plate with an anti-E2 antibody and competition for antibody binding sites was established. The in situ bismuth-coated carbon electrodes were used for detecting the cadmium ions (Cd(2+)) released during the acid dissolution step. After optimization, the well-defined sharp anodic stripping voltammograms curves of the E2 concentration ranging from 50 to 1000 pg/mL was recorded, and the lowest detection limit was 50 pg/mL with 6% reproducibility and 7% repeatability. Finally, the assay was applied to tap water and wastewater samples. The detection limits were 52.56 ± 0.125 pg/mL for tap water and 51.42 ± 0.453 pg/mL for wastewater. These results show that the assay exhibited sensitive analytical performance in E2 detection with high sensitivity and accuracy with satisfactory results.
More Related Videos
08:28Validated Immunochemical Assay for Comprehensive Determination of the Human Epidermal Growth Factor Receptor 2 Released from and Bound to Cells
Published on: May 9, 2025
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Linear-Scan (E vs Time)