Related Experiment Video
Updated: May 12, 2026

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Percutaneous closure of tricuspid paravalvular leak
Mariel E Turner1, Wyman W Lai, Julie A Vincent
1Division of Pediatric Cardiology, Columbia University College of Physicians and Surgeons, Morgan Stanley Children's Hospital of New York-Presbyterian, New York, New York.
Abstract:
While transcatheter closure of mitral and aortic paravalvular leaks has been well-described, there are no prior reports of such procedures for prosthetic tricuspid valves. We describe our experience with percutaneous closure of a tricuspid paravalvular leak in a 34-year-old patient with a history of tricuspid atresia. He had previously undergone repair with placement of a right atrium-to-right ventricle conduit and most recently, placement of a bio-prosthetic tricuspid valve. He subsequently developed significant tricuspid paravalvular leak with symptoms of severe right heart failure. His clinical status was improved following successful transcatheter closure of the defect.
Related Concept Videos
Mitral Stenosis III: Medical Management
Pericarditis III: Medical Management
Mitral Regurgitation III: Medical Management