Auto-calibration approach for k-t SENSE.

Irene P Ponce1, Martin Blaimer, Felix A Breuer

  • 1Department of Experimental Physics 5, University of Würzburg, Würzburg, Germany.

Summary

This study introduces auto-calibrated k-t SENSE, improving spatial resolution in dynamic imaging. This method enhances temporal fidelity without increasing scan times, offering high-quality reconstructions.

Related Concept Videos

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient01:10

Calibration Curves: Correlation Coefficient

In a linear calibration curve, there is a value called the calibration coefficient, denoted by 'r,' which measures the strength and the direction of association between two variables. The correlation coefficient value ranges from −1 to +1. A value of +1 indicates a perfect positive linear correlation, −1 denotes a perfect negative correlation, and 0 implies no correlation between the two variables. A positive correlation value establishes that as one variable increases, the other increases, and...
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Linearization and Approximation01:26

Linearization and Approximation

Linearization is a mathematical technique used to approximate complex, nonlinear functions with simpler linear models in the vicinity of a chosen reference point. The method is based on the idea that, although a function may be difficult to evaluate exactly, its behavior near a specific input value can often be closely approximated by the tangent line at that point. This approach is particularly useful when small deviations from a known value are involved.Consider the square root function, for...
Kendall's Tau Test01:16

Kendall's Tau Test

Kendall's tau test, also known as the Kendall rank coefficient test, is a nonparametric method for assessing association between two variables. This test is particularly useful for identifying significant correlations when the distributions of the sample and population are unknown. Developed in 1938 by the British statistician Sir Maurice George Kendall, the tau coefficient (denoted as τ) serves as a rank correlation coefficient, with values ranging from -1 to +1.
A τ value of +1 indicates that...