Low and optically thin cloud measurements using a Raman-Mie lidar.
Yonghua Wu1, Shuki Chaw, Barry Gross
1Optical Remote Sensing Laboratory, The City College of New York, New York, New York, USA. yhwu@ccny.cuny.edu
Applied Optics
|April 10, 2013
Summary
Daytime measurement of low-altitude clouds is improved using Raman-elastic lidar. This technique enhances optical depth retrieval accuracy by correcting for aerosol interference, providing better insights into cloud properties.
Area of Science:
- Atmospheric Science
- Cloud Physics
- Remote Sensing
Background:
- Accurate measurement of optically thin, low-altitude clouds during daytime is challenging.
- Existing lidar techniques can be affected by aerosol interference, limiting retrieval accuracy.
Purpose of the Study:
- To evaluate the capability of a Raman-elastic lidar system for daytime measurement of low-altitude optically thin clouds.
- To improve the accuracy of low-cloud optical depth retrievals by correcting for aerosol influences.
Main Methods:
- Utilizing nitrogen Raman and elastic-scattering returns for optical depth derivation.
- Applying a combined Raman-elastic lidar approach to correct for aerosol effects.
- Mapping lidar ratio profiles to assess cloud microphysical properties.
Main Results:
- Demonstrated significant improvement in Mie retrievals of low-cloud optical depth after aerosol correction.
- Achieved good agreement between corrected Mie retrievals and direct Raman retrievals.
- Generated lidar ratio profiles consistent with water phase cloud models.
Conclusions:
- Raman-elastic lidar is a viable tool for daytime measurement of low-altitude optically thin clouds.
- Aerosol correction using combined lidar returns substantially enhances optical depth retrieval accuracy.
- Lidar ratio variability analysis offers insights into cloud droplet distribution near cloud edges.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...