Related Experiment Video
Updated: May 12, 2026

Absorbent Microbiopsy Sampling and RNA Extraction for Minimally Invasive, Simultaneous Blood and Skin Analysis
Published on: February 21, 2019
Preparation and examination of monolithic in-needle extraction (MINE) device for the direct analysis of liquid
Monika Pietrzyńska1, Adam Voelkel, Katarzyna Bielicka-Daszkiewicz
1Poznań University of Technology, Institute of Chemical Technology and Engineering, Poznań, Poland. monikapietrzynska@gmail.com
Abstract:
Combination of extraction and chromatographic techniques opens NEW possibilities in sample preparation area. Macroporous poly(styrene-divinylbenzene) (PS-DVB) monoliths were prepared by in situ polymerization in stainless steel needles. The surface of stainless steel needle was modified earlier by the silane coupling agent. Monolithic materials located inside needles were used as the in-needle extraction device. Scanning electron microscope (SEM) images were obtained for nine monoliths. Spectra of prepared materials were also performed with the use of two techniques: Attenuated Total Reflectance (ATR) and Fourier Transform Infrared Spectroscopy (FTIR). The new monolithic in-needle extraction (MINE) devices were used in the preparation of a series of test water samples for chromatographic analysis. The extraction of phenolic compounds from water samples was carried out by pumping liquid samples through the MINE device. Obtained results indicate a high efficiency of in-needle extraction systems based on monolithic materials. Breakthrough volume and the sorption efficiency of prepared monolithic in-needle extraction devices were determined experimentally. The achieved recovery was close to 90%, and determined LOQ values varied between 0.4 and 6 μg.
More Related Videos
07:55Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
Published on: June 21, 2019
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Related Concept Videos
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...